Dimensions
(see page 8)
Cleaning
(see page 20)
Test
certificate
(see page 8)
Special
information
for
UK
(see page 15)
Fault
Insufficient water
Crossflow, hot water being forced
into cold water pipe, or vice versa,
when mixer is closed
Spout temperature does not cor-
respond with temperature set
Temperature regulation not possible
Instantaneous heater didn't work with
thermostat
Shower or spout dripping
English
Cause
- Supply pressure inadequate
- Regulator filter dirty
- Shower filter seal dirty
- Backflow preventers dirty or leaking - Clean backflow preventers, ex-
- Thermostat has not been adjusted
- Hot water temperature too low
- thermo cartridge calcified
- Filters are dirty
- check valve hasn't moved back
- Flow limiter in handshower isn't
removed
- Dirt or sedimentation on valve seat,
shut-off unit damaged
Assembly
(see page 6)
Spare
parts
(see page 14)
Operation
(see page 12)
Remedy
- Check water pressure (If a pump
has been installed check to see if
the pump is working).
- Clean filter in front of the mixer and
on the MTC-thermo cartridge
- Clean filter seal between shower
and hose
change if necessary
- Adjust thermostat
- Increase hot water temperature to
42 ºC to 65 ºC
- Exchange thermo cartridge
- Clean the filter / exchange filter
- Exchange check valves
- Remove flow limiter
- Clean or exchange shut-off unit
5