Herunterladen Inhalt Inhalt Diese Seite drucken
Vorschau ausblenden Andere Handbücher für Tectron 37 419:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 4

Programme table

The infrared electronics provide seven preset programmes for selection.
Programme
1
Temporary shutoff*
2
Automatic flushing*
Flush interval
Usage-dependent
Usage-independent
Detection zone
3
Pre-flushing*
4
Intermediate flushing*
1
*
Cleaning mode can be activated when temporary shutoff is activated. In cleaning mode, flushing is not triggered
for 3 minutes, even if an object is detected.
2
*
Automatic flushing serves to ensure water hygiene in the event of long-term non-utilisation of the fitting. Flushing is initiated
after 24 hours (usage-independent) or 24 hours/72 hours after the fitting was last used (usage-dependent).
3
*
When pre-flushing is active, a flow volume of 3 litres is flushed 2 seconds after an object is detected.
4
*
When intermediate flushing is active, flushing is initiated every 60 minutes if an object is continuously detected (max. 3x).
Fault/cause/remedy
Fault
Cause
LED in electronics flashing
• Obstacle during calibration
continuously after calibration
• Servo motor defective
No flushing
• Water supply interrupted
• No voltage (LED in electronics not
• Electronics defective (LED not flashing or
• Servo motor defective
• Plug-in connector without contact
• Detection zone of sensor system set too
• Servo motor and electronics not calibrated - Calibrate servo motor
• No flushing with manual actuation
• Cleaning mode activated
Water flowing continuously • Waste not closing
Undesired flushing
• Detection zone of sensor system set too
Flow volume too low
• Servo motor defective or not calibrated
• Residual flow rate in cistern too high
• Flow rate in cistern too low
1
2
Active
Active
Active
Active
24 h
24 h
x
x
75 cm
75 cm
Inactive
Active
Active
Active
flashing)
permanently on)
low
high
(incomplete rotation)
3
4
5
Active
Active
Active
Active
Active
Active
24 h
24 h
72 h
x
x
x
75 cm
95 cm
75 cm
Inactive
Inactive
Active
Active
Inactive
Active
Remedy
- Perform calibration again, ensuring there is no
obstacle in the adjustment range of the servo
motor
- Replace servo motor
- Open isolating valve in cistern
- Switch on power supply or replace transformer
- Replace electronics
- Replace servo motor
- Attach plug-in connector
- Increase detection zone using remote control
(special accessories 36 206)
- Connect or check pneumatic hose
- Terminate cleaning mode prematurely or wait 3
minutes
- Maintain or replace waste, see technical
product information for cistern
- Calibrate servo motor
- An opposing object is detected. Reduce
detection zone using remote control
(special accessories 36 206)
- Replace or calibrate servo motor
- Push residual flow slider at waste downwards
- Turn float of filler valve upwards
6
7
Active
Inactive
Active
Inactive
72 h
-
-
x
-
75 cm
75 cm
Inactive
Inactive
Active
Active
6

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis