Maintenance and cleaning
W A R N I N G
Possible death or severe injury from hazardous electrical voltage!
• Prior to reaching into the water, isolate (switch off and disconnect) all units/devices used in the water.
• Isolate the device (disconnect from the power supply) before carrying out any work on it.
If necessary, clean the unit with clear water using a soft brush.
• Ensure that no moisture can enter the unit.
Remedy of faults
Issue
Lamp does not light up
Reduced performance/ Dimming
Water in the lamp body
Light is flickering
Wear parts
• Bulb
Repair
Neither the transformer nor the spotlight can be repaired in the event of damage to the cables or the housing and must,
therefore, be replaced.
Spare parts
The use of original parts from OASE ensures continued
safe and reliable operation of the unit.
Please visit our website for spare parts drawings and spare
parts.
Disposal
N O T E
Do not dispose of this unit with domestic waste.
• Render the unit unusable beforehand by cutting the cables and dispose of the unit via the return system
provided for this purpose.
10
Cause
− device does not receive power
− bulb defective
− bulb contacts have corroded
− glass lens is dirty
− gasket is defective / not installed correctly
− bulb contacts corroded
www.oase-livingwater.com/spareparts
Remedy
− check power connection
− change bulb
− clean contacts
− clean lens
− check gasket and replace, if necessary
− clean contacts