Enter the following key combination to do so:
81 03 to 10 incorrect entries
Example for setting 6 incorrect entries after which the code lock is to be blocked for 87 minutes:
81 06
The alarm block can be deactivated using a valid ID card, by entering a valid code or with a
valid card + user number.
Factory setting = after 10 invalid ID cards, 10 incorrect entries of the code of
1 valid ID card and then 5 incorrect user number entries. The code block is set
to 1 minute. The yellow LED is lit once and the buzzer sounds once at 10 second
intervals while the block is active. As soon as the block is deactivated the
buzzer emits a long beep tone.

10.13 Door State Monitoring

Enter the following key combination to deactivate this function:
9
00
#
Enter the following key combination to activate this function:
9
01 to 99 seconds
This function has two performances:
Method 1:
The door remains open longer than the set period of time (01 to 99 seconds).
In this case the buzzer sounds a constant signal tone to remind you to close
the door. As soon as the door is closed the signal tone stops.
Method 2:
If the door is forced open - the buzzer sounds as an alarm signal - even if the
door is closed again, the signal tone continues to sound from the buzzer. The
alarm can only be deactivated using a valid ID card, by entering a valid code
or with a valid card + valid user number.
Factory setting is "9-00".
50
*
01 to 99 minutes
*
87
#
#
#