Herunterladen Inhalt Inhalt Diese Seite drucken

Grohe Euroeco Cosmopolitan E 36 273 Anleitung Seite 7

Vorschau ausblenden Andere Handbücher für Euroeco Cosmopolitan E 36 273:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 4
II. Solenoid valve, see fold-out pages II and III
1. Loosen screw (G1) and remove wall plate (G), see Fig. [11].
2. Disconnect plug-in connector between solenoid valve and
electronics, see Fig. [13].
3. Screw out solenoid valve (M) and replace or clean
filter (M1).
Assemble in reverse order.
III. Remove and clean mousseur (13 951), see fold-out
page I.
Assemble in reverse order.
IV. Wall plate with electronics, see fold-out pages II and III
1. Loosen screw (G1) and remove wall plate (G), see Fig. [11].
2. Loosen screw (F) and remove spout (E), see Fig. [14].
3. Disconnect plug-in connector between solenoid valve and
electronics, see Fig. [15].
4. Disconnect plug-in connection between switched-mode
power supply and electronics.
5. Remove screws and washers (N) and remove housing (I).
6. Replace wall plate (G) with electronics.
Assemble in reverse order.
Fault / Cause / Remedy
Fault
Cause
Water not flowing
• Water supply interrupted
• Filter upstream of solenoid valve blocked
• Solenoid valve defective
• Plug-in connector of solenoid valve without
contact
• No voltage
- Switched-mode power supply defective
- Plug-in connector without contact
- Electrical supply
Switched off
• Hands not in detection zone
• Cleaning mode activated
Water flowing
• Solenoid valve defective
continuously
• Thermal disinfection activated
Undesired water flow • Sensor system detection zone set too high
for local conditions
• Automatic flushing activated
Flow rate too low
• Mousseur dirty
• Filter in solenoid valve dirty
• Filter in connection hose/thermostat dirty
• Water supply restricted
Water temperature
• Temperature incorrectly set
too high or too low
• Dirty filters or defective non-return valve
(only 36 336)
For latest prices and delivery to your door visit MyTub Ltd - 0845 303 8383 - www.mytub.co.uk - info@mytub.co.uk
Thermostatic cartridge
(Only in conjunction with wall-mounting box 36 336.)
I. Non-return valve, see fold-out pages II and III
1. Loosen screw (G1) and remove wall plate (G), see Fig. [11].
2. Remove thermostat (O), see Fig. [16].
3. Remove filter (P).
4. Unscrew nipple (Q) (left-hand thread).
5. Remove nut (R).
6. Remove non-return valve (S).
Assemble in reverse order.
II. Thermostatic cartridge, see fold-out pages II and III
1. Loosen screw (G1) and remove wall plate (G), see Fig. [11].
2. Loosen screw (J) and remove cap (K), see Fig. [17].
3. Remove thermostatic cartridge (T).
Assemble in reverse order.
Replacement parts
see fold-out page I (* = special accessories)
Care
For directions on the care of this fitting, please refer to the
accompanying Care Instructions.
Remedy
- Open shut-off valves, isolating valves
- Clean filter
- Replace solenoid valve
- Attach plug-in connector
- Replace switched-mode power supply
- Check plug-in connectors
- Switch on voltage supply
- Hold hands directly under the spout
- Deactivate cleaning mode or wait 3 minutes
- Replace solenoid valve
- Wait 3.5 or 11 minutes
- Reduce range using remote control
(special accessory, Prod. No.: 36 206)
- Wait 1 - 10 minutes
- Clean or replace mousseur
- Clean filter
- Clean or replace filters
- Check supply lines, open shut-off valves,
isolating valves
- Adjust temperature
- Replace filters and non-return valve
4

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis