Herunterladen Inhalt Inhalt Diese Seite drucken

Lenze EMZ9371BC Betriebsanleitung Seite 83

Keypad xt
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Copy parameter set from the keypad to the standard device
Step
1.
Connect the keypad to
standard device 2
2.
Inhibit controller
3.
Select submenu 7.1,
"Load/Store", from "Param
managm" in menu 7
4.
Change to the code level
5.
Change to the parameter level
6.
Select the correct copy function
l
Copy all available parameter sets (PAR1 ... PAR4, if required FPAR1) into the standard
device:
– Standard device with
function module
application I/O,
INTERBUS,
PROFIBUS−DP, LECOM−B,
DeviceNet, CANopen
– Standard device with all
other function modules
l
Only copy the module−specific parameter set FPAR1 into the function module:
– Only possible with
standard devices
including function
module INTERBUS,
PROFIBUS−DP, LECOM−B,
DeviceNet, CANopen:
EDK9371BC DE/EN/FR 3.2
Parameterisation 8200 vector/8200 motec
Key sequence
S
z y Z Y
Z
V
z
z
l
Transmit parameter sets
Action
The drive coasts
Use the arrow keys to change to the
"Load/Store" submenu
Display C0002 "Param managm"
Display "0" and "READY"
The settings stored in the standard
device or in the function module are
overwritten.
Copy PAR1 ... PAR4 and FPAR1:
ð
Set "70" "Key−>F1&PAR1−4"
Copy PAR1 ... PAR4:
ð
Set "10" "Keypad−>PAR1−4"
Copy FPAR1:
ð
Set "40" "Keypad−>FPAR1"
7