Selecting Low and High Power Mode
combustion
low
start
stop
As shown in <Fig. 3>
As shown in <Fig. 4>
As shown in <Fig. 5>
LOW Mode:
Low concentration sterilized water is obtained after 1-minute operation.
HIGH Mode:
High concentration sterilized water is obtained after 3-minute operation.
Operation Mode
As shown in <Fig. 5>, the selected mode lights up red, while the Start Button lights up
white. The light inside the Spray Bottle slowly lights up.
Within 3 seconds after you select the mode, the appliance starts to produce electrolyzed
water after the light in the bottle is lit and the 3 consecutive beeps are heard.
If you want to stop the appliance in the middle of the water production process, the
appliance goes into Standby Mode when you press and hold the Start Button for 5
seconds.
flashing
high
Insert the Spray Bottle into the Body. Plug the
appliance. As shown in <Fig. 3>, white LED on
the power button lights up.
The appliance switches to 'Standby Mode' with
a beep to prepare for the electrolysis process.
When the appliance is in the Standby Mode and
the START key is pressed for 5 seconds, it goes
into the Sleep Mode or the appliance goes into
to Sleep Mode automatically if the button is not
pressed for 3 minutes.
If you want to return to standby mode from sleep
mode, press the button for 1 second. With a
beep, the appliance returns to standby mode.
Selection Mode
As shown in <Fig. 4>, the red LED lights up in
the LOW Mode when the Start button is pressed
once. Once the button is pressed again, the red
LED lights up in HIGH Mode.
While in Standby Mode, LOW (Low) Mode is
activated by a beep when the START button is
lightly pressed. To switch to HIGH Mode, you
need to press the button again within 3 seconds.
Each time you press the button, the operating
mode changes between LOW and HIGH.
Pressing the button for 5 seconds will put the
appliance in Standby Mode.
25