The fragrance is not dosed until the steam cabin temperature has reached 30 °.
Stage 5
If no automatic fragrance dosage is available, the fragrance can be added to the
steam jet by hand.
4.5. Colour change light (RGB LED) Key 8
(Additional equipment)
With Key 8
The colours change in a gentle, fi xed sequence. By pressing the 8 key again, the
colour shade currently lit up can be stopped. Pressing again switches off the colour
changer. If a steam generator has special equipment, max. 2 RGB lights (special
accessories) can be connected. 2 further lights can be controlled via an additional
module.
8.5 Exhaust air
(Additional equipment)
The exhaust air fan switches on automatically after the steam generator has been
switched off with a follow-up time of 5 min. and ensures that the steam is extracted
from the steam cabin. This reduces the residual humidity in the cabin. In program
step P5, a follow-up time of 5 -20 minutes can be selected for the fan (see Customer
Programming).
1.8. Supply air
(Additional equipment)
The supply air fan switches on at the same time as the steam production and en-
sures the supply of fresh air and improves the development of steam in the cabin.
The supply air quantity can be regulated in 5 stages. On reaching the set nominal
temperature, the fan continues to run for approx. 5-7 s.
1.9. Free output No. 1 Relay 14
Function programming in the customer programming
P0 = 00 Relay always off
P0 = 01 Possible activation of the relay only if the generator is operating.
P0 = 02 Relay active when RGB = ON
1.10 Free output No. 2 Relay 15
Function can be programmed in the customer programming
Possible activation of the relay only if the generator is operating.
P1 = 00 off
P1 = 01 on
18
=
Continuous operation of the pump to fi ll, without temperature
limitation.
the colour change light is activated.