24
THE INLET HOSE FILTER AND
THE VALVE FILTER
It could be necessary to clean the filters
when:
• The appliance does not fill with wa-
ter.
• The appliance fills with the water for
a long time.
1
2
2
1
3. Put a container below the recess of
the drain pump to collect the water
that flows out.
4. Press the two levers and pull for-
ward the drainage duct to let the
water flow out.
5. When the container is full of water,
put the drainage duct back again
and empty the container. Do steps
4 and 5 again and again until no
more water flows out from the
drain pump.
6. Pull back the drainage duct and
turn the filter to remove it.
7. Remove fluff and objects from the
pump.
8. Make sure that the impeller of the
pump can turn. If this does not oc-
cur, contact the service centre.
9. Clean the filter under the water tap
and put it back in the pump into
the special guides.
10. Make sure that you tighten correct-
ly the filter to prevent leakages.
11. Put the flap back and close the
drain pump door.
• The indicator of button
and the display shows the related
alarm. Refer to 'Trouble shooter and
service'.
WARNING!
Disconnect the mains plug from
the mains socket.
flashes