Herunterladen Inhalt Inhalt Diese Seite drucken

Installation Diagram - Steinbach SPEED CLEAN Serie Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
1.7
Resultant damages
We cannot be responsible for damages to the product if the product is not used in accordance with the instructions provided.
Before loosening any threaded connections on the filtration system, be sure that the suction and pressure hoses are
ATTENTION:
closed to prevent water flow over the motor. Damages caused by flooding the pump are not covered under the
warranty.
2.
Technical specifications – Speed Clean 75 / 50 ø
Sand filter system (filter container 400 mm ø) with self-priming pump, pre-filter, multi-valve, pressure gauge, and special filter bottom strainer.
With quick-release toggle latch and filter pallet, equipped for use with a UV disinfection unit.
Speed Clean 75
Flow volume (Q) at 4 mWS
Operating pressure
Rated voltage
Output
Protection class
Cable length including plug
Max. ambient temperature
Sand volume
Dimensions (LxBxH)
Weight (without filler)
2.1

Installation diagram

1.
Filter container
2.
Recirculation pump speed
3.
Hose connexion between filter pump and 6-way central valve
4.
6-way central valve
5.
From pool (untreated water) - including ball cock upstream of the filter pump on the installed side
6.
To pool (purified water) - including ball cock downstream of the multi central valve installed side
7.
drainage line (slurry) - downstream of the 6-way central valve to discharge installed side
8.
Fill opening (under tension)
9.
Pressure gage
10. Container drain
11. Base drain or open drainpipe connexion, DN 100, installation side
12. 2 ¼ opening for UV pipes and/or 3 KW heating element
3.
Installation
Proper installation, operation and maintenance of your filtration system are the best guarantees of good filtration quality
NOTE:
and a long service life. We recommend that you take note of the information presented in this handbook.
3.1
Outside installation:
Please note that the minimum space between the pool on the pump conforms to national safety standards (e.g. Austria: 2 m).
An absolutely level 0.60 x 0.60 m surface made of filter gravel (crushed rock) or compressed concrete with an open drainage attachment or
drainage ditch for backwash water is necessary.
Piping is carried out with flexible spiral ø 32/38 mm hose.
When the swimming pool is winterised (prior to the onset of frost), the filtration system has to be drained, dismounted
ATTENTION:
and stored in a location protected from frost, or packed in a frost-resistant manner. For storage, the handle on the 6-way
central valve should be set between two positions to relieve tension on the spring.
The pump is self-priming, but it should be mounted below the water level to allow water to flow to the pump. This relieves stress on the pump
and should increase its service life.
To operate the system out of doors, a 30 V 1N – AC 50 Hz grounding contact socket outlet (for damp areas) is necessary. This should be
installed by a locally licensed electrician at a distance of at least 3 m from the pool edge.
The grounding contact socket outlet should be equipped with an I
NOTE:
Speed Clean 50
3
7.0 m
/h
Flow volume (Q) at 4 mWS
1.5 bar
Operating pressure
230V 1N – AC /50Hz
Rated voltage
750 Watt
Output
IP X5
Protection class
1.5 m
Cable length including plug
35°C
Max. ambient temperature
approx. 25 kg
Sand volume
600 x 420 x 840 mm
Dimensions (LxBxH)
approx. 18 kg
Weight (without filler)
3
5.5 m
/h
1.5 bar
230V 1N – AC /50Hz
375 Watt
IP X5
1.5 m
35°C
approx. 12 kg
600 x 420 x 650 mm
approx. 15 kg
≤ 30mA residual current-operated protective device.
Δ
N
- 2 -

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Speedclean75Speedclean50

Inhaltsverzeichnis