5. MAINTENANCE AND INSPECTION

5.1 Maintenance

• Check the water supply device and the release often. You should avoid the condition of no water or air
entering into the system as this will influence the unit's performance and reliability. You should clear the pool/
spa filter regularly to avoid damage to the unit as a result of a clogged filter.
• The area around the unit should be dry, clean and well ventilated. Clean the side heating exchanger regularly
to maintain good heat exchange and conserve energy.
• The operation pressure of the refrigerant system should only be serviced by a certified technician.
• Check the power supply and cable connection often. Should the unit begin to operate abnormally, switch it off
and contact your qualified technician.
• Discharge all water in the water pump and water system, so that freezing of the water-inlet the pump or water
system does not occur. You should discharge the water at the bottom of the water pump if the unit will not be
used for an extended period of time. You should check the unit thoroughly and fill the system with water fully
before using it for the first time after a prolonged period of no usage.

5.2 Trouble Shooting Guide

Malfunction
Water-inlet temperature sensor
failure
Water-outlet temperature sensor
failure
Coil sensor failure
Ambient sensor failure
The temperature difference between
the water-inlet and water-outlet is
too large
Defrost cycle
First level frost protection in winter
Second level frost protection in
winter
High pressure protection
Low pressure protection
Flow switch failure
PP6 alarm code occurred 3 times in
30 minutes
Defrosting cycle
Communication failure
12
LED
Controller
The sensor is open or there is a
PP1
short circuit
The sensor is open or there is a
PP2
short circuit
The sensor is open or there is a
PP3
short circuit
The sensor is open or there is a
PP5
short circuit
Water flow volume is not enough,
PP6
water pressure difference is too
low/too large
PP7
Outlet water is too low
Ambient or inlet water temperature
PP7
is too low
Ambient or inlet water temperature
PP7
is even lower
Gas System pressure is too high,
or water flow rate is too low, or
EE1
evaporator is clogged, or air flow
is too low
Gas System pressure is too low, or
EE2
air flow is too low or evaporator coil
is clogged
No water/little water in water
EE3
system
EE5
Water flow rate not enough
Defrost Code
Display
LED controller or PCB connection
EE8
failure
Reason
Check or change the sensor
Check or change the sensor
Check or change the sensor
Check or change the sensor
Check the water flow volume, or
system obstruction.
Check the water flow volume or
outlet water temperature sensor
Check the high pressure switch and
the gas system pressure to see
whether the gas loop is blocked.
Check the water flow volume. Check
that the evaporator coil is clean.
Check the fan rotation speed
Check the low pressure switch and
the gas system pressure to see
whether there is a leak
Check the water flow volume, check
if the water pump and flow switch
has failed
Check the water flow rate, check if
the water system is jammed
Check the wire connection
Resolution