4. USAGE AND OPERATION

4.1 The Functions of the LED Controller

Press
to set and check
the operation data
Press `SET` to change the
parameter value
4.2 How to set operation parameter
In Off Mode: press button " ◀ ▶ " to enter operation parameters.
Press "SET" to start setting (parameter from 00-09, see Operation Parameter
Table).
Under parameter setting, press " ◀ " or " ▶ " to select data for parameter
from 00-09,
If no button is pressed, the LED will display the water-inlet/water-outlet temperature
(when running) or the clock (unit not running).
When running, you can press " ◀ ▶ " to check current parameters, but the data
cannot be changed.
Parameter 0
Set the water-inlet temperature
in cooling mode (8-28°C)
default setting: 27°C
Parameter 3
Set defrost cycle start-up
temperature (-30-0°C)
default setting: -6°C
8
LED screen
Press the key to set the
Press the key to set the
time to turn on the unit
time to turn off the unit
Parameter 1
Set the water-inlet temperature
in heating mode (15-40°C)
default setting: 27°C
Parameter 4
Set defrost cycle stop
temperature (0-30°C)
default setting: 13°C
Press`MODE` to change the
running mode
Press
to turn on and
turn off the unit
Press `CLOCK` to set
the time
Parameter 2
Total working time of
compressor after defrost
cycle
Parameter 5
Max. duration of defrost cycle
(0-15 min.)
default setting: 8 min.