9. Mounting and venting of pump

1. Fit the bracket for lever arm to the pump.
2. Fit the lever arm to the bracket.
Pump cut-in and cut-out levels:
With lever arm: From 260 mm to 50 mm.
3. Place the float switch of the pump on the
lever arm.
4. Fit the non-return valve and the fitting in
the pump discharge port.
The valve flap must be uppermost.
5. Place the pump in the bottom of the tank
(left or right side can be used).
6. Fit the hose between the pump
discharge port and the tank discharge.
7. Fasten the electric cable of the pump to
the tank.
8. Vent the pump: 1. Connect the pump to the power supply.* 2. Pour water into the tank until the pump
starts. 3. Move the pump gently from side to side until it starts delivering water.
9. Fit the cover to the tank.
* For electrical connection: See installation and operating instructions for the pump.