Herunterladen Inhalt Inhalt Diese Seite drucken

Cutting Cycle Operation - Elite EHB-350DGSVIP Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

switch (K), that means that pump motor is running
wrong direction. Change two of the phases.
2.
Select manual operation mode:
Turn switch (M) to the left.
3.
Use switch (K) to raise the saw bow.
4.
Move the material feeler (P, Fig 7-4) up to the top.
Figure 7-4: Material Feeler
5.
Use switch (L) to open the vise by hydraulic cylinder.
5.
Lift and disengage the vise pawl (Q, Fig 7-5). Open the
vise by hand.
Figure 7-5: Vise pawl and rack
6.
Place stock material between the vise jaws.
7.
Close the vise by hand, leave a small gap.
8.
Use switch (L) to clamp the material
CAUTION:
For cycle cuts of same size material, leave a small gap (3~5mm)
between stock material and vise jaws.
Make sure the vise pawl is down and engaged with the rack,
before closing the vise with hydraulic cylinder.
Make sure the hydraulic cylinder safely clamps and unclamps
the material.
If vise clamping fails, the lamp (J, Fig 7-1) is lit.
CAUTION:
For cycle cuts of same size material, leave a small gap (3~5mm)
between stock material and vise jaws.
Make sure the hydraulic cylinder safely clamps and unclamps
the material.

7.5 Cutting Cycle Operation

Make sure the power source is same as indicated on the
machine ID-label.
Connect the machine to power source. Turn the main switch
(A, Fig 7-1) on. The power lamp (C) will be lit.
1.
Press button (E) to start the hydraulic pump.
Note:
If the hydraulic pump fails to start, or if pump starts but
15