Herunterladen Inhalt Inhalt Diese Seite drucken

Electrical Connections; Grounding Instructions; Extension Cords - Elite EHB-350DGSVIP Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

3)
Release the saw arm counter-balance spring
4)
Empty the coolant tank
5)
Carefully clean and grease the machine
6)
If necessary, cover the machine.
4.8 Dismantling (out of service)
General rules:
If the machine is to be permanently demolished and/or
scrapped, divide the material to be disposed of according to
type and composition, as follows:
1)
Non-composite cast iron or ferrous materials are
recyclable raw materials, so they may be taken to an iron
foundry for re-melting after having removed the
contents (classified in point 3).
2)
Electrical components, including the cable and electronic
material (magnetic cards, etc.), fall within the category of
material classified as being assimilated to urban waste
according to the laws of your local, state, or federal
government, so they may be set aside for collection by
the public waste disposal service;
3)
Old mineral and synthetic and/or mixed oils, emulsified
oils and greases are considered hazardous to the
environment, so they must be collected, transported and
disposed of at a special waste disposal service.
CAUTION:
The legislation concerning waste disposal and recycling is in a
constant state of evolution, therefore is subject to changes.
The user must keep informed of the regulations at the time of
disposal as these may differ from those described above.

5.0 Electrical Connections

WARNING:
All electrical connections must be done by a qualified
electrician in compliance with all local codes and ordinances.
Failure to comply may result in serious injury.
The EHB-350DGSVIP Metal Band Saw is rated at 3~400V, PE,
50Hz power supply, the machine comes with a plug designed
for use on a circuit with a grounded outlet.
Mains connection and any extension cords and plugs used
must comply with the information on the machine license
plate.
The mains connection must have a 16A surge-proof fuse.
Only use extension cords marked H07RN-F, with wires 1,5mm
or more.
The total length of cord may not exceed 18 Meter
Power cords and plugs must be free from defects.
Connections and repairs to the electrical equipment may only
be carried out by qualified electricians.
The machine is equipped with 1.8m power cord and plug.
Before connecting to power source, be sure the main switch is
in OFF position.

5.1 Grounding instructions

This tool must be grounded. In the event of a malfunction or
breakdown, grounding provides a path of least resistance for
electric current to reduce the risk of electric shock. This tool is
equipped with an electric cord having an equipment-
grounding conductor and a grounding plug. The plug must be
inserted into an appropriate outlet that is properly installed
and grounded in accordance with all local codes and
ordinances.
WARNING:
Improper connection of the equipment-grounding conductor
can result in a risk of electric shock. Check with a qualified
electrician or service person if you are in doubt as to whether
the outlet is properly grounded. Do not modify the plug
provided with the tool.
The green/yellow conductor is the equipment-grounding
conductor. If repair or replacement of the electric cord or plug
is necessary, do not connect the equipment-grounding
conductor to a live terminal.
Use only 3-wire extension cords with grounding plugs.
Repair or replace damaged or worn cord immediately.

5.2 Extension cords

The use of extension cords is discouraged; try to position
machines near the power source. If an extension cord is
necessary, make sure it is in good condition.
An undersized cord will cause a drop in line voltage resulting in
loss of power and overheating.
Only use extension cords marked H07RN-F, with wires 1,5mm
or more.
The total length of cord may not exceed 18 Meter
Extension cords and plugs must be free from defects.