7.6 REPLACING KNIFE, DIE AND DIE PLATE

Remove
– Disconnect tool from air supply.
– Remove two cylinder screws (15/9), stop plate
(13/10) and strap holding pawl (15/8).
– Remove four cylinder screws (15/6).
– Withdraw base plate (15/5) from housing.
– Loosen two cylinder screws (15/3) and remove and
replace die plate (15/2).
Ejector bolts (15/13) and springs (15/14)
could falling out.
– Loosen two cylinder screws (15/7) and carefully
remove and replace die (15/4).
– Remove and replace knife (15/1).
Install
– Install the parts in reverse order.
Secure new cylinder screws (15/3), (15/6)
and (15/7) with Loctite 243. Before moun-
ting the base plate (15/5), ensure that the milled sur-
face of the bolt 15/11) points downwards.
– Set cut-off depth after assembly (see chapter 7.3).

7.7 CLEANING THE TOOL

– The tool should be regulary cleaned. Especially the
tension wheel and the jaw unit should be kept clean.
The easiest way to do this, is to use compressed air
and to blow out the dust (wear eye protection).