6. Pour salt tablets into the salt supply container
Use only salt tablets acc. DIN 19604.
7. Connect transformer to the device
o Remove cover to the salt container and hood
o Plug the cable shoes of the transformer into the
controller
8. Replace hood and cover, guide the cable out of the
back of the device
9. Connect the softening device to the mains via the
transformer

10.Programming the softening device

10. Programming the softening device

10.1 Display and operating keys

CURRENT TIME
REGENERATION
10.2 Basic settings for commissioning - time, raw
water hardness and regeneration time
1. There is a connection to the power supply
o Display Current time flashes
CURRENT TIME
2. Set the time by pressing + or -
3. Confirm with MENU / OK
o Display Hardness flashes
HARDNESS
4. Set the raw water hardness by pressing + or -
The hardness of the raw water can be inquired
from the water distribution company.
5. Confirm with MENU / OK
o Display Regeneration time flashes
REGENERATION
TIME
6. Set the desired time for the regeneration by pres-
sing + or -
Honeywell GmbH
GB
MENU / OK
11
o Recommended time 2:00
7. Confirm with MENU / OK
8. Starting regeneration
o Press the Regeneration key for 5 seconds
o Display Regeneration active flashes
o The time is displayed in the display during the
regeneration process
REGENERATION ACTIVE
9. After the end of the regeneration (duration 45
minutes)
o Display Regeneration active goes out.
o The time is displayed
10.The device is ready for operation
10.3 Setting the mix water hardness
It is recommended to set a residual water hard-
ness of at least 8°dH to avoid corrosion
damages.
It is recommended to check the output water
hardness regularly (2 times a year).
1. Setting the mix water hardness by turning the screw
at the base of the diluting device
o Use screwdriver
o Turn counter-clockwise = increase water hard-
ness on output side
o Turn clockwise = decrease water hardness on
output side
2. Check the mix water hardness at a tapping point
o Open tapping point completely to ensure sufficient
flow
3. Readjust by turning the screw if necessary