Shaking incubatorS
Si500, Si600
instructions for use
1. introduction
Thank you for purchasing this piece of Stuart
equipment. To get the best performance from
this equipment please read these instructions
carefully before use. Before discarding the
packaging check that all parts are present and
correct.
item number
HH179(S)
HH180(S)
SI500-89 or SI600-89
I/FCALUSB
RSSL1 or SI600/1
7001096
For your own safety and that of others
please read and understand the safety
advice given below before using the
equipment.
2. Safety advice before use
If the equipment is not used in the manner
described in this manual and with
accessories other than those recommended
by Stuart, the protection provided might
be impaired.
This equipment is designed to operate under the
following conditions:
❖ For indoor use only
❖ Use in a well ventilated area
❖ Ambient temperature range +5ºC to +40ºC
❖ Altitude to 2000m
❖ Relative humidity not exceeding 80%
❖ Mains supply fluctuation not exceeding 10%
❖ Over-voltage category II IEC60364-4-443
❖ Pollution degree 2
Operational warnings and conditions:
caution: hEaVY obJEct. Do not
attEmpt to liFt or carrY thE unit
alonE.
Description
UK mains lead with plug
EU mains lead with plug
Instruction manual
USB cable
Securing bars (4)
Guarantee card
❖ Use with a minimum distance all around of
200mm (100mm at the rear) from walls or
other items.
❖ Not to be used to heat or mix materials which
could result in liberation of gases, or cause
explosions or implosions.
❖ Not to be used or placed in areas known to
be hazardous.
❖ Never move or carry the unit when in use or
connected to the mains electricity supply.
❖ When lifting or moving the unit, always lift
from the base.
❖ Do not use in a hazardous atmosphere or
with hazardous materials.
❖ Ensure that the load is balanced.
❖ Do not attempt to stop movement by hand.
❖ Do not lean on the open door of the SI600 as
this could cause the unit to tilt, particularly
when the platform is extended. Furthermore,
do not leave the incubator unattended with
the door open.
❖ Fitting of feet brackets to the SI600 is
required prior to use (see 4.3).
❖ In the case of mains interruption, the unit will
not restart on restoration of the electricity
supply. In the case of mechanical interruption,
(e.g. motor stall), the unit will continue
operating on removal of interruption.
❖ Mechanical energy can lead to breakage of
glass vessels. Use with care.
uSE caution whEn rEmoVing
VESSElS From thE incubator aS
partS maY bE hot.

3. general description

The Stuart SI500 and SI600 orbital incubators are
ideal for mixing and aerating various biological
samples under accurate temperature controlled
conditions. The rotating platform has a digital
speed setting providing a smooth, uniform
circular motion with an orbit of 16mm. The
speed range is 30 to 300rpm. There is also an
adjustable digital countdown timer that
automatically stops after the set time (1 second
steps to 1h, 1 minute steps to 24h or 1h steps to
9 days). The shaking platform has a drawer
mechanism for easy access to the incubation
vessels. The temperature is controlled by a simple
"press to set" system in 0.1ºC intervals from
ambient +5ºC to 60ºC.