Herunterladen Inhalt Inhalt Diese Seite drucken

Error Messages; Technical Data - Baumer Z-PA-EI-H Betriebsanleitung

Programmierzubehör für inkrementale drehgeber
Inhaltsverzeichnis

Werbung

13

Error messages

GB
Error warning
Please
connect
encoder
Battery is Low
Encoder ERROR!
Rx Error!
or
Encoder ERROR!
Please repeat
Encoder ERROR!
Bad Flash CRC
Bad Resolution!
Out of Range
ERROR: Button n
Not Set
Encoder ERROR!
Different Type
You pressed:
xxx/xxx nnn/100
14

Technical data

Please refer to the data sheet Handheld Programming Tool
Z-PA-EI-H.
Baumer_Handheld-Programming-Tool-Z-PA-EI-H_OI_DE-EN_1708.pdf
Error cause
No encoder connection
Cable defect
Encoder defect
Low battery status
Incomplete encoder data
transfer
Possible root cause:
Programming cable inap-
propriate or too long
Noise interference (e.g.
running engine)
Cable defect
Connection problems
Encoder defect
Exceeding the maximum
pulse number
Makro button (n= 1 - 4)
not assigned
Makro button assignment
does not coincide with
encoder type
Text mode activity
Error messages, Technical data
Troubleshooting
Check connection
Exchange batteries
Check connection
Check cabling
Eliminate noise interference
Please contact Baumer
Select pulse number in line
with encoder specification
Assign Makro button, see
functionality description.
Connect related encoder
type or reassign Makro
button, see functionality
description
Wait for approx. 15 seconds
 31