4.)
Write Output
GB
4.1) Write Output
5.)
Referencing (Write Ref. Type)
5.1) Write Ref. Type
6.)
Write pulse sequence
6.1) Write Pulse Seq.
Baumer_Handheld-Programming-Tool-Z-PA-EI-H_OI_DE-EN_1708.pdf
Delivered is the current signal output level of the connected
encoder.
Use key arrows to change to TTL or HTL.
Delivered is current width and blanking of the reference
pulse of the connected encoder.
Changing the reference type is by the arrow keys and entry
confirmation by ENTER. Available options depend on the
encoder type (see encoder data sheet).
Delivered is the current pulse sequence A leading to B at
clockwise (CW) shaft rotation when looking at the encoder
flange.
Changing the pulse sequence is by the arrow keys and
entry confirmation by Enter.
Choose CW or CCW as an option.
Opposite rotational direction entails the pulse sequence
being also in opposite direction.
Rotation
A leads B (CW)
A leads B (CCW)
A leads B (CW)
A leads B (CCW)
Setting
B
B
B
B
Explanations on functionality
Pulse sequence
A
A
A
A