4. Product Information

4.1 Intelligent technology

Urinal installations in the public and semi-public sector must satisfy very stringent
requirements - hygiene, reliability and low cleaning/maintenance costs are the primary
concern.
The DuraStyle urinal satisfies these requirements: The urinal offers touchless flushing
thanks to an electronic control unit developed especially by Duravit. The electronics
operate in conjunction with an infrared sensor that automatically detects arrival of a
user and subsequently initiates flushing when the user moves away from the urinal
(detection time/dwell time 9 sec.). Since the DuraStyle urinal thinks logically, passersby
or even objects that remain stationary within the detection range of the controls for
some time do not trigger spurious flushing - the unit adjusts continuously to the
surrounding conditions. In addition, the DuraStyle urinal offers several free selectable
service and flushing programs as well as a manually adjustable flush duration. Auto-
matic flushing every 12 hours to maintain hygiene prevents the build-up of unpleasant
odours.

4.2 User-friendly maintenance

The DuraStyle urinal is especially easy to service and maintain - the control unit is
maintenance-free; the solenoid valve is replaced with little effort after removing the
stainless steel cover beneath the control unit. Both the pre-shutoff valve and the
dirt-collecting screen can be accessed easily without having to remove the stainless
steel cover. The battery can be exchanged after removing the vandal-proof control unit
in just a few quick steps and then replacing it.

4.3 Factory settings (defaults)

Detection time/dwell time:
Flush duration (full flush):
Please refer to section 5.4.1 for information on manually adjusting the flush duration
(min. 1 sec., max. 4 sec.).
9 sec.
2 sec.