Maintenance

The EXPERT / INTEGRA PRO compact flash series is in need
of little maintenance by the user. The unit should be dry cleaned
from dust from time to time. Before cleaning separate the unit
from the mains outlet.
Caution: Under no circumstances is any part of the equipment
to be opened. The equipment is not user serviceable and there
is dangerous high voltage. In the event of difficulty notify your
dealer.

Replacement of fuses

In case of a broken fuse 9 replace fuse only, when the unit is
switched off and separated from the mains outlet.
Attention:
Never repair or bridge fuses.
Only use "fast" fuses with the required value:
Fuse for operation with modeling light 300W/G6.35 Halogen
EXPERT PRO series:
INTEGRA PRO series:
Only use fuses in accordance with EN 60127-2/1 or
respectively IEC 127-2/1. A wrong fuse may cause an explosion
of the halogen modeling lamp.

Replacement of modeling lamp

Replace modeling lamp only, when unit is switched off and
unplugged from the mains outlet.
Make sure that the modeling lamp is protected by the specified
fuse (see paragraph replacement of fuses above).
Use only halogen lamps as modeling light with the maximal light
output specified as follows:
EXPERT PRO series: 300W/G6.35/230V (Code 128)
INTEGRA PRO series: 300W/G6.35/115V (Code 1280)
Make sure that the modeling lamp for units of the INTEGRA
PRO serie corresponds to the mains voltage.
2 AF
4 AF
and 300W/G6.35/230V (Code 128), resp.
HENSEL Studiotechnik