ASSEMBLY

Before assembly, check that the product is complete and has not suffered any damage during
transport.
ASSEMBLY must be carried out by a specialised company.
The specialised company and the operator must observe, comply with and understand all of
the following instructions in this assembly and operating manual. For the system to function
as intended, it must be installed professionally in compliance with the technical rules
applicable to the planning, construction and operation of the entire system.
Risk of injuries due to blown-out metal chips!
Metal chips may cause eye injuries.
Wear safety goggles!
Malfunctions caused by residues! Proper functioning is not guaranteed.
Visually check that there are no metal chips or other residues in the connections!
It is important that metal chips or other residues are blown out!
Install with suitable tools, if required.
Regarding screw connections, use a second spanner to brace against the connection nozzle.
Do not use unsuitable tools, such as pliers.
Product damaged through incorrect installation direction
Proper functioning is not guaranteed.
Observe the installation direction (marked on the product with an arrow
Screw connections
Tank regulator damaged through incorrect installation.
May cause gas leaks and malfunctioning.
Follow the correct sequence to prevent leaks.
Do not install the tank regulator under tension.
When you have tightened the POL coupling nut, do not twist the tank regulator any more.
Tighten connections only when they are not pressurised.
The installation steps are described using a pressure regulator with US POL
connection as an example (British POL connection and POL connection soft)
1. Apply a drop of oil to the conical sealing surface of the POL connector.
2. Screw the POL connection on to the withdrawal valve of the gas cylinder hand-tight.
3. Tighten the piping on the outlet nozzle while bracing against the flat of the pipe coupling.
4. Tighten the POL connector on the withdrawal valve.
During installation make sure that the withdrawal valve and the piping are aligned. Do not
install the tank regulator under tension. We recommend the "regulator support for CE tanks",
Part no. 02 510 40.
To install the connections, see CONNECTIONS in the assembly manual.
If compression/separation connectors are used in the building, a 1st stage regulator with
maximum 1 bar shut-off pressure of the safety overpressure shut-off valve (OPSO) must be
used.
10 / 16
1st stage regulator Type VSR 0523, VSR 0524 and VSR 013
).
part no. 05 239 50 j