Individual pushbutton
The drive adapter, adapter ring and push-in pin are normally al-
ready mounted. The driver adapter must be secured along the axis
with an M6x1 screw, toothed washer and plain washer.
Some drive adapters have slot recesses of different widths and/or
depths for different slot barrels.
Before installing the barrel, measure from the end of the barrel to
the middle of the drive adaptor and mark this point on the barrel.
DO NOT drill near the drive!
Mount the drive in the barrel without using force.
Connect the drive adapter of the tubular drive to the roller tube
properly, as follows:
Size of
Roller shutter
drive
tubes–Ø [mm]
[mm]
6 - 10 mm
Ø 58
diecast drive
adapter
85 - 1 mm
Ø 58
aluminium drive
adapter
Work, including maintenance tasks, on the electrical instal-
lation must always be performed by an authorised qualified
electrician.
All applicable standards and regulations for the electrical installa-
tion must be complied with.
A pole isolator with at least a mm contact gap per pole is es-
sential for the connection of the control system to the mains supply
(EN 605).
Only use switching elements with mechanical or electrical locking
which guarantee that in the event of a direct change of direction,
the drive is switched voltage-free for at least 0.5 s.
Torque
Fastening screws
max. [Nm]
for drivers (4 x)
flat-headed sheet-metal
10
screw 9,5 x 10 DIN 798
flat-headed screws
10
M8 x 16 DIN 7991