Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1

Spare parts

1
thermoelement
2
shut off unit with selector
3
knob for thermoelement
4
knob for shut off unit
5
mousseur cpl.
6
non return valve DW 16
7
filter
8
ball s-unions
9
Elastop shut off unit
10 knob for shut off unit
11 safety set for temperature control 96470000
12 safety set for flow control
13 escutcheon
XXX = Colors
000 chrome
090 chrome/gold
880 satin chrome
Fault
Insufficient water
Crossflow, hot water is forced into
cold water pipe, or vice versa,
when mixer is closed
Spout temperature does not
correspond with the temperature
set
Temperature regulation not possible - MTC-thermo cartridge calcified
Shower or spout dripping
Instantaneous heater didn't work
with thermostat
English
94282000
96509000
96516XXX
96517XXX
13485000
95033000
95039000
13989000
94149000
96518XXX
96430000
96428XXX
Cause
- Supply pressure inadequate
- Filter are dirty
- Shower filter seal dirty
- Backflow preventers dirty or
leaking
- Thermostat has not been
adjusted
- Hot water temperature too low
- Dirt or sedaimentation on valve
seat, shut-off unit damaged
- Ecostop ring isn't removed
- Flow limiter in handshower isn't
removed
- Filter are dirty
- Non return valve didn't move
back
Remedy
- Check mains pressure
- Clean filter in front of the
mixer and on the MTC-thermo
cartridge
- Clean filter seal between shower
and hose
- Clean backflow preventers,
exchange if necessary
- Adjust thermostat
- Increase hot water temperature
to 42 °C to 65 °C
- Exchange MTC-thermo cartridge
- Clean or exchange shut-off unit
- Remove ecostop ring (12)
- Remove flow limiter
- Clean the filter/exchange filter
- Exchange non return valves
9