Herunterladen Inhalt Inhalt Diese Seite drucken

Eberle E100 Bedienungs- Und Installationsanleitung Seite 30

Raumtemperaturregler nicht programmierbar
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

The controller must be installed directly onto the wall or on a flush-mounting socket.
1. Loosen the screws below the battery cover.
2. Remove the front cover by pressing the button on the bottom of the housing. (see Fig. 1).
3. Attach the back plate to a flush-mounting socket using suitable wall plugs and screws.
4. Complete the wiring to the heating source according to the wiring diagram inside the product
or below. (see Fig. 2).
5. Mount the front cover by pushing it fully onto the back plate.
6. Tighten the screws.
7. Install the 2 AA batteries provided.
The controller is now installed and will automatically start to control the room temperature accord-
ing to the pre-set Comfort (On) temperature.
All important functions are set ex-factory. If you wish to change any of the settings, please refer to
the options in the User Guide, see page 25.
According to the heating type, refer to Installer Options see page 30.
Fig. 1
30
L
N
Fig. 2
H
C
H = Heating, actuators normally closed
C = Heating, actuators normally open or cooling only
C
RELAY
On
Off