Specifications - Mitsubishi Electric AL-ASI-BD Hardwarehandbuch

Aktor-sensor-interface-module
Vorschau ausblenden Andere Handbücher für AL-ASI-BD:

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 4
This manual contains text, diagrams and explanations which will guide the reader in the
ENG
correct instruction and operation of the AL-ASI-BD and AL2-ASI-BD AS-Interface module. It
should be read and understood before attempting to install or use the unit. Further information
can be found in the
Manuals.
Caution
• Persons trained in the local and national electrical standards must replace the AL-ASI-BD
or AL2-ASI-BD.
• Turn off the power supply when you install or remove the AL-ASI-BD or AL2-ASI-BD.
• Replace the cover after removing the AL-ASI-BD or AL2-ASI-BD.
• Under no circumstances will Mitsubishi Electric be liable or responsible for any
consequential damage that may arise as a result of the installation or use of this
equipment.
1. INTRODUCTION
The AL-ASI-BD and AL2-ASI-BD Actuator Sensor Interface board module (Hereafter referred to as the
AL-ASI-BD) is used in conjunction with the following
communication over an Actuator Sensor Interface (AS-interface) network.
Table 1. Applicable Controller
Model Name of Interface
AL-ASI-BD
AL2-ASI-BD
The AL-ASI-BD connects onto the main body of the
interface network (Input 4 points, Output 4 points). A maximum of 31 slaves can be connected to form an
AS-interface network. Power for the communication is supplied over the AS-interface bus by the AS-
interface power supply. The communication signal is superimposed over the power supply on the AS-
interface bus.

2. SPECIFICATIONS

For general specifications please refer to the
Table 2. Hardware Communication Specifications
Item
Number of I/O
I/O Refresh Time
Network Distance
External Power Voltage
External Power Current
Consumption
Complies with
Table 3. Software Communication Specifications
Item
Station Number
IO Code
ID Code
Data Bit
D0 - D3
P0
Parameter Bit
P1,P2,P3
M6
System Bit
M7
Control Bit
N1
*1 Function to reset input signal (E01 - E04) when AS-interface communication is cut for 70 ms or more.
α
α
Hardware or
2 Hardware Manual, and
AL-20MR-A, AL-20MR-D, AL-20MT-D
All AL2 series
α
α
(
4 Input (in. E01-E04) 4 Output (Out. A01-A04)
Max. 5ms
Max. 100m
Typ. 30.5V DC (AS-interface Power supply)
40 mA or less
AS-interface Certification, CE
Set by Master Station (Factory default 0)
7
F
Input Output 01 - 04 (E01 - E04, A01 - A04)
Communication monitor (set by default).
Unused
"ON" when communication Error of AS-interface occurs
"ON" when communication Error by AS-interface power fail occurs
ON: Connect to AS-interface network
OFF: Unconnected to AS-interface network
α
α
(
and
Model Name of Controller
α
series controller, forming a slave station for an AS-
α
or
2)Series Hardware Manual.
Content
Content
*1
α
α
or
2 Series Programming
α
2) series controller for data