Herunterladen Inhalt Inhalt Diese Seite drucken

Declaration Of Conformity; General Remarks Regarding The Ce Marking; Data Connections; Signal Connections - Hameg Instruments HM7042-5 Handbuch

Power supply
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

G e n e r a l r e m a r k s r e g a r d i n g t h e C E m a r k i n g
KONFORMITÄTSERKLÄRUNG

DECLARATION OF CONFORMITY

DECLARATION DE CONFORMITE
DECLARACIóN DE CONFORMIDAD
Hersteller / Manufacturer / Fabricant / Fabricante:
HAMEG Instruments GmbH · Industriestraße 6 · D-63533 Mainhausen
Die HAMEG Instruments GmbH bescheinigt die Konformität für das Produkt
The HAMEG Instruments GmbH herewith declares conformity of the product
HAMEG Instruments GmbH déclare la conformite du produit
HAMEG Instruments GmbH certifica la conformidad para el producto
Bezeichnung / Product name /
Dreifach Netzgerät
Designation / Descripción:
Triple Power Supply
Alimentation triple
Alimentación triple
Typ / Type / Type / Tipo:
HM7042-5
mit / with / avec / con:
Optionen / Options /
Options / Opciónes:
mit den folgenden Bestimmungen / with applicable regulations /
avec les directives suivantes / con las siguientes directivas:
EMV Richtlinie 89/336/EWG ergänzt durch 91/263/EWG, 92/31/EWG
EMC Directive 89/336/EEC amended by 91/263/EWG, 92/31/EEC
Directive EMC 89/336/CEE amendée par 91/263/EWG, 92/31/CEE
Directiva EMC 89/336/CEE enmendada por 91/263/CEE, 92/31/CEE
Niederspannungsrichtlinie 73/23/EWG ergänzt durch 93/68/EWG
Low-Voltage Equipment Directive 73/23/EEC amended by 93/68/EEC
Directive des equipements basse tension 73/23/CEE amendée par 93/68/CEE
Directiva de equipos de baja tensión 73/23/CEE enmendada por 93/68/EWG
Angewendete harmonisierte Normen / Harmonized standards applied /
Normes harmonisées utilisées / Normas armonizadas utilizadas:
Sicherheit / Safety / Sécurité / Seguridad:
EN 61010-1:2001 (IEC 61010-1:2001)
EN 61010-1: 1993 / IEC (CEI) 1010-1: 1990 A 1: 1992 / VDE 0411: 1994
Überspannungskategorie / Overvoltage category / Catégorie de surtension /
Categoría de sobretensión: II
Verschmutzungsgrad / Degree of pollution / Degré de pollution /
Nivel de polución: 2
Elektromagnetische Verträglichkeit / Electromagnetic compatibility /
Compatibilité électromagnétique / Compatibilidad electromagnética:
EN 61326-1/A1: Störaussendung / Radiation / Emission:
Tabelle / table / tableau 4; Klasse / Class / Classe / classe B.
Störfestigkeit / Immunity / Imunitee / inmunidad:
Tabelle / table / tableau / tabla A1.
EN 61000-3-2/A14: Oberschwingungsströme / Harmonic current emissions /
Émissions de courant harmonique / emisión de corrientes armónicas: Klasse /
Class / Classe / clase D.
EN 61000-3-3: Spannungsschwankungen u. Flicker / Voltage fluctuations and flicker
/ Fluctuations de tension et du flicker / fluctuaciones de tensión y flicker.
Datum / Date / Date / Fecha
01.09.2004
Unterschrift / Signature / Signatur / Signatura
M. Roth
Manager
14
Subject to change without notice

General remarks regarding the CE marking

HAMEG measuring instruments comply with the EMI norms. Our tests
for conformity are based upon the relevant norms. Whenever different
maximum limits are optional HAMEG will select the most stringent
ones. As regards emissions class 1B limits for small business will be
applied. As regards susceptability the limits for industrial environments
will be applied.
All connecting cables will influence emissions as well as susceptability
considerably. The cables used will differ substantially depending on the
application. During practical operation the following guidelines should
be absolutely observed in order to minimize EMI:

1. Data connections

Measuring instruments may only be connected to external associated
equipment (printers, computers etc.) by using well shielded cables.
Unless shorter lengths are prescribed a maximum length of 3 m must
not be exceeded for all data interconnections (input, output, signals,
control). In case an instrument interface would allow connecting several
cables only one may be connected.
In general, data connections should be made using double-shielded
cables. For IEEE-bus purposes the double screened cable HZ72 from
HAMEG is suitable.

2. Signal connections

In general, all connections between a measuring instrument and the
device under test should be made as short as possible. Unless a shorter
length is prescribed a maximum length of 3 m must not be exceeded,
also, such connections must not leave the premises.
All signal connections must be shielded (e.g. coax such as RG58/U).
With signal generators double-shielded cables are mandatory. It is
especially important to establish good ground connections.
3. External influences
In the vicinity of strong magnetic or/and electric fields even a careful
measuring set-up may not be sufficient to guard against the intrusion
of undesired signals. This will not cause destruction or malfunction of
HAMEG instruments, however, small deviations from the guaranteed
specifications may occur under such conditions.
HAMEG Instruments GmbH

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis