5.3 Access to the protection fuse

1) WARNING!
Switch off the appliance!
2) remove the cover from the Red Line+,
3) disconnect the regulator,
4) remove the regulator cover,
5) remove the protection fuse(T3,15AH250V).
Notice: neither display nor operation if out of order

6. STARTING UP

Model
+
RedLine
3
+
RedLine
6
+
RedLine
9
+
RedLine
12
* with a manufacturer tolerance of + or – 5 %
appliance protection index: IP 45

6.1 Before starting up, check

• the hydraulic fittings are correctly tightened,
• there is no leak,
• the appliance is correctly fixed to the wall,
• the connections of the electric cables are correctly tightened,
Incorrectly tightened cables may cause overheating of terminals,
• the appliance is correctly connected to the Earth,
• the water contained in the appliance is not frozen,
6.2 Starting up
• run manually the filtering pump for an operational test of the heater or at the time of the first rise in
temperature in the pool (once the pool is at the right temperature, put the filtering back on automatic),
• purge the air from circuit and make sure no air remains in the appliance,
• check the flow rate is between 5 and 30 m³/h,
• switch on the mains supply circuit breaker,
if the flow rate is higher than 30 m per hour, fit by by-pass,
• switch on the 30 mA différentiel circuit breaker, at the head of the line,
• set the required temperature according to section 5.2,
• press the
switch,
If the appliance is on demand, the led "reg" blinks for 15 seconds then turns steady => heating in
progress.
Observation:
- when the appliance heats the water ("reg" led lit up), if the filter stops or if the water flow rate is less than 5
m³/h, the appliance stops heating ("reg" led flashing). The flow controller "CD" is open,
- when the pool reaches the desired temperature, the appliance stops heating ("reg" led off).

6.3 Checking

Make sure that the heater stops when:
• decreasing the required temperature on the control thermostat,
• filtration is switched off,
• when pressing key
Important! Before any intervention, make sure the unit is switched off.
Additional technical characteristics:
L-shaped immersion heater at nominal voltage*
3 kW
6 kW
9 kW
12 kW
.
In event of frost, the heater shall not operate.
.
4)
6
5)
Net average weight
3,5 Kg
3,5 Kg
4 Kg
4 Kg