6. Commissioning

6.1 Initialisation phase

6.2 Indication of the selected relay

6.3 Error message

The VBus
/PWM interface adapter is equipped with a
®
7-segment LED display that can indicate the selected relay
or the current operational status.
When the interface adapter is connected to a controller
for the first time, a short initialisation phase will be run.
During this phase, the LED display flashes first the er-
ror code f, then the error code u until the controller
connected has been recognised. After a short time, the
address of the selected relay will be indicated.
If the error codes do not disappear or if an a is indicated
instead of the relay address, see chapter 6.3 for error code
descriptions and troubleshooting measures.
The relay addressed via the DIP switches is displayed by the
7-segment-LED at the front of the adapter.
As the LED can only indicate one figure, the decimal digit is
replaced with a dot when indicating relays 10 - 16:
= Relay 1
1
2 = Relay 2
= Relay 3
3
4 = Relay 4
5 = Relay 5
6 = Relay 6
= Relay 7
7
8 = Relay 8
If an error occurs, the display flashes an error code:
a = The output addressing is faulty. The relay addressed
does not exist
Î Address a valid relay
f = The VBus
®
connection is faulty
Î Check the VBus
cable
®
u = The controller connected is not recognised by the
device
Î Wait for about one minute. If the error code does
not disappear, contact the manufacturer
9 = Relay 9
0. = Relay 10
= Relay 11
1.
2. = Relay 12
3. = Relay 13
4. = Relay 14
5. = Relay 15
6. = Relay 16
15
|