8.
Zubehör
Battery Pack BP-04-N
9.
Fehlercheckliste Connection Kit / Battery Pack
▶
Fehler
Mögliche Ursachen
Kein Signal
Keine Stromversorgung
Strombegrenzung im BP-04-N
aktiv
D
4
▶
Abhilfe
Speisegerät richtig verbinden
BP-04-N: Batterien wechseln
BP-04-N: Auto shut-off deaktivieren
Netzgerät verwenden
Mikrophon mit einem Strombedarf ≤ 150 mA verwenden
(das D-01 kann nicht mit dem BP-04-N betrieben werden)
1.
Introduction
This manual contains essential information for
the operation and care of the product you have
purchased. Please read the instructions carefully
and completely before using the product. Please
keep this manual where it will be accessible at all
times to all current and future users.
Additional information, in particular concerning
available accessories and Neumann service part-
ners, can be found on our website: www.neumann.
com. Information about service partners can also
be obtained by telephone: +49 (0) 30 / 41 77 24 - 0.
The following related fi les are available in PDF
format in the Downloads section of our website
www.neumann.com:
•
KMD Operating Manual – digital miniature mi-
crophones
•
BP-04-N Battery Pack Operating Manual
Additional information concerning the digital
microphone interface can be found in standard
AES 42 on the website: www.aes.org/standards.
Our Neumann online forum enables Neumann
users worldwide to share their experiences.
Through its integrated archive function, the forum
has developed into an extensive knowledge pool.
2.
Safety instructions
The Connection Kit has the intended purpose of
supplying power to digital microphones in accor-
dance with the international standard AES 42, and
of making available the audio data stream from the
microphone in the AES/EBU format or the S/PDIF
format.
•
Connect only digital microphones that comply
with the AES 42 standard to the microphone
input.
•
Repairs and servicing are to be carried out only
by experienced, authorized service personnel.
Unauthorized opening or modifi cation of the
equipment shall void the warranty.
•
Use the equipment only under the conditions
specifi ed in the "Technical data" section.
As a power supply, use only the plug-in pow-
er supply provided or the BP-04-N Battery
Pack which is available as an accessory. The
use of power supplies with unstable voltages
in particular can damage the Connection Kit
and the connected microphone.
•
Allow the equipment to adapt to the ambient
temperature before switching it on.
•
Do not operate the equipment in a damaged
condition.
•
Always lay out cables so that there is no risk of
tripping over them.
•
When disconnecting a cable, always pull only
on the connector and not on the cable itself.
•
Ensure that li quids and electrically conductive
objects unless required for operation are kept
at a safe distance from the equipment and its
connections.
•
Do not use solvents or aggressive cleansers for
cleaning purposes.
•
Dispose of the equipment in accordance with
the regulations applicable to the respective
country.
Disclaimer:
The product is sold "as-is" and the customer is as-
suming the entire risk as to the product's suitabi-
lity for his needs, its quality and its performance.
In no event will Neumann be liable for direct,
indirect, special, incidental or consequential da-
mages resulting from any defect in the product or
from its use in conjunction with any microphones/
products from other manufacturers, even if advi-
sed of the possibility of such damages.
3.
Brief description
The Connection Kit serves to supply power to
digital Neumann microphones which are in accor-
dance with the AES 42 standard but beyond that
are capable of working with lower phantom volt-
age. The audio microphone signal is made avail-
able at the output of the connection kit in S/PDIF
format or AES/EBU format, depending upon the
product model. Attention: The possibilities for
remote control and synchronization which are
provided by the AES 42 standard cannot be used
with the Connection Kit. That's the purpose of the
Neumann digital microphone interface DMI-2.
4.
Equipment supplied
•
AES/EBU module or S/PDIF module
•
Plug-in power supply with adapters for the EU,
UK and US
•
Operating manual
•
Packaging
US
GB
5 5