5. Starting up/entering the electricity price
(euro/kWh)
Note
• If the energy cost meter cannot be started, then
press the reset button (5) for a few seconds.
• The rechargeable battery is charged during operation.
• The internal rechargeable battery will discharge if
the timer switch is not used for longer periods of
time. Plug the energy cost meter into a mains plug
for approx. 24 hours every 3 months to charge the
internal rechargeable battery.
Press the FUNC button to view the following displays in
succession:
• VOLTac: mains voltage, mains frequency and time are
displayed
• AMP: current, power factor and time are displayed
• WATT: output, power factor and time are displayed
• WATT max: maximum output is displayed
• kWh: kWh consumed, power factor and time are
displayed
• TOTAL PRICE; TOTAL ON TIME: total price and usage
duration are displayed
• PRICE1: Price 1 is displayed
• PRICE2: Price 2 is displayed
5.1 Setting the time
• Press the FUNC button until CLOCK is shown in the
display.
• Press the SET button and use the UP button to set the
day of the week.
• Press the SET button and use the UP button to set
the hour.
• Press the SET button and use the UP button to set
the minutes.
• Press the SET button to save your settings.
• Press the UP button to choose between 12-h and
24-h mode.
5.2 Setting price
• Press and hold the FUNC button for a few seconds
until COST/Kwh is shown in the display.
• Press the SET button to set Price 1. Use the SET button
to select the digit you would like to enter.
• Enter the required value using the UP button.
• Press the SET button and use the UP button to set the
corresponding days of the week.
• Press the SET button and use the UP button to set the
corresponding time.
• Press the SET button to save your settings.
• After setting Price 1, press the FUNC button to set
Price 2. Then repeat the steps described above.
• After setting Price 2, press the FUNC button to set the
maximum overload value.
• Press the SET button and then select the digit you
would like to enter.
• Enter the required value using the UP button.
• Press the SET button to save your setting.
• Press and hold the FUNC button for a few seconds to
return to the standard display.
5.3 Standby
The display will go out if no action is carried out for a
period of 10 seconds. Press any button to return to the
display.
6. Measurement
Note
• Precise measurement results even for small appliances.
• The voltage and power draw of the connected
devices may not exceed 230 V and 3680 W.
• Note the information specified on the nameplate(s)
of the connected device(s).
• If you connect an electrical appliance that draws more
than 3680 W, then the display shows OVERLOAD.
• It is advisable to measure the power consumption
of a device for an extended period of time and then
calculate its annual consumption.
• Plug the energy cost meter into a conventional mains
socket.
• Plug the electrical device to be measured or its mains
plug into the socket on the energy cost meter. The
consumption measurement commences automatically.
• Press the FUNC button to change the display mode.
• Unplug the electrical device from the energy cost
meter or the energy cost meter from the mains socket
to end the measurement.