Standard press seal HSD-SSG
Contents
1
Publishing notes ...............................................13
2
Explanation of symbols ....................................13
3
Required tool and auxiliaries ...........................13
4
Description ........................................................13
5
Preparing for assembly ....................................13
5.1
Mount the standard press seal from the
outside of building ...........................................13
5.2
R etrofitted splitting of standard press seal
(HSD 150/200/250 und 300-SSG) on already
laid pipes ...........................................................13
5.3
Mount the standard press seal from the
inside of building ..............................................14
1
Publishing notes
Copyright © 2018 by
Hauff-Technik GmbH & Co. KG
Dept.: Technical Editing
Robert-Bosch-Straße 9
89568 Hermaringen, GERMANY
Tel.
+49 7322 1333-0
Fax
+49 7322 1333-999
E-mail
office@hauff-technik.de
Internet
www.hauff-technik.de
Reproduction of these assembly instruction – even in
extracts – in the form of reprint, photocopy, on electro-
nic data media or using any other method requires our
written consent.
All rights reserved.
Subject to technical alterations at any time and without
prior announcement.
These assembly instruction is component of the product.
Printed in the Federal Republic of Germany
2
Explanation of symbols
1
Work stages
Effect/result of a work step
1
Reference numerals in drawings
3
Required tool and auxiliaries
For correctly assembly of the the standard press seal HSD
100-SSG or HSD 150-SSG, HSD 200-SSG, HSD 250-SSG
and HSD 300-SSG you will need the following tools and
aids in addition to the usual tools:
Assembly set for HSI 150-DG/HRK SSG (Article no.:
2102200600), consisting of:
1 Torque spanner 4-20 Nm, 1/4 inch
1 Extension 100 mm, 1/4 inch
2 Extensions 150 mm, 1/4 inch
1 Adapter for cordless screwdriver, square, 1/4 inch
1 M6 socket, wrench size 5, 1/4 inch with spherical
head
Auxiliaries:
4
Description: HSD 200-SSG 110-160 (see fig.: 1).
Legend for fig.: 1
1
2
3
4
5
6
5
1
Legend for fig.: 2
1
2
5.1 Mount the standard press seal from
2a
2b
5.2 R etrofitted splitting of standard
3a
3b
Art. Nr.: 5090032038
Rev.: 04/2019-01-21
1 M8 socket, wrench size 6, 1/4 inch with spherical
head
1 Lubricant GM (Art.Nr.: 080420000)
1 Cutter knife
1 Cleaning cloth
Description
Rear press segments
Allen screw
Front press segments
Blind plug
Elastomer segment/Rubber press ring
(Grade: EPDM or NBR)
Built-in inspection opening
Preparing for assembly
Clean the core drilling/liner and media line.
Level out any chips and/or voids which may be present.
Check the diameter tolerance of the core drilling/
liner (D -1+2 mm) and media line (d) (see table
1), as well as outer or drilling dimension of the press
seal (see fig.: 2).
Diameter (D) of the core drilling/wall sleeve
Diameter (d) of the medium pipe
the outside of building
Remove the blind system cover from the standard
press seal HSD 150-SSG 75-110, HSD150-SSG
70-112-SL and HSD 200-SSG 110-160 und HSD
200-SSG 110-162-SL (see fig.: 3a).
Fold out and pull out the blind plug on the HSD
100-SSG 18-65-SL and HSD 100-SSG 25-63 (see
fig.: 3b).
press seal (HSD 150/200/250 und
300-SSG) on already laid pipes
To split the standard press seal, loosen and remove
a screw on the division cut (see fig.: 4a).
To split the standard press seal HSD 150-SSG 75-110
und HSD 200-SSG 110-160, loosen and remove a
screw (see fig.: 4b).