Basic function:
Light value (
Required remote control buttons:
Funktion button
+
(press configuration buttons
1-5 within 10 seconds)
Configuration button
Configuration button
Configuration button
Configuration button
Configuration button
10 seconds after LED feedback (for the set
level) a rapid flashing sequence on the LED
is displayed (approx. 2 to 3 seconds) to show
operational readiness of the luminaire.
44
Lux)
LUX
red control LED in the luminaire flashes
(feedback of last setting)
1
red control LED in the luminaire acknowledges 1x
2
red control LED in the luminaire acknowledges 2x
3
red control LED in the luminaire acknowledges 3x
4
red control LED in the luminaire acknowledges 4x
5
red control LED in the luminaire acknowledges 5x
press =
press for 5 secs. + 5 = teach-in mode*
(see teach-in mode, page 48)
press = daylight (continuous operation)
press = 300 lux
press = twilight
press = darkness
saved threshold value
press =