System messages
L O A d
C r d
S E r
r E S
Power supply
The Butler S2 can be powered by an external AC/DC power supply or via Power-
over-Ethernet (PoE). The power supply must deliver a supply current of 250 mA.
Only use the e:cue power supply. The PoE supply voltage is 48 V DC. Power-over-
DMX is not supported.
When using Power-over-Ethernet do not connect any power supply
physically to the DC Input of the Butler S2. Otherwise the power feed
from Ethernet will not be recognized.
e:net
Use standard CAT5 (RJ45) network cabling for e:net.
Please remember that e:net requires an isolated network segment
and cannot operate properly when using e.g. internet or video/audio
streaming in the same network simultaneously.
»LOAd« Butler S2 is in bootloader mode. This display may result
from an incomplete firmware update or when the system button
is pressed while powering up the Butler S2.
»Crd« Card error, the microSD card is missing, a file is corrupt
or a read error occured. Press the button, if the error reap-
pears rewrite the card.
»SEr« Serial number error. The reading of the serial number
failed. Repower system. If the error reappears contact your
e:cue service.
The Butler S2 executes a soft reset after the System button was
pressed for at least four seconds.
Setup Manual - Butler S2