AIR FLOW
-Occurs when the air flow meter is
METER
disconnected.
FAILURE
-Occurs when the water
FROST RISK
temperature falls below a certain
value.
-Occurs when the stove has
exceeded 1800 hours of
SERVICE
operation or 2000 Kg pellet,
DUE
since the previous servicing.
8 INSTALLER
8.1 Menu installer settings
The following instructions are intended only for technical personnel specialised in heating units.
Changing the parameters in a non-appropriate way can cause serious damage to people, the units and
the environment. In this case, the construction declines any liability.
To access the INSTALLER SETTINGS menu, press button P3 - MENU and use the scroll buttons to display the item
INSTALLER SETTINGS and then press button P3 - MENU. Use the scroll buttons to display access key 10 and
press button P3 - MENU.again. The various parameters can be displayed with the scroll buttons; access with button
P3 - MENU, edit them with the scroll buttons and exit with ESC.
It contains the adjustment parameters given below.
Parameter code
10-01
10-02
10-03
10-04
10-05
10-06
10-07
The Manufacturer reserves the right to make technical or aesthetic changes to the products at any time without notice.
The drawings, measurements, diagrams and any other configurations are given only by way of example.
-The controller does not detect
the quantity of combustion air
and does not shut down the
stove; it only excludes the air
flow meter functions.
-The stove control detects the
water temperature below 6°C
and displays a message.
-Extraordinary
notice.
For increasing or decreasing auger OFF duration for all powers.
For increasing or decreasing fume extractor speed for all powers, by a
value of 5% for each unit.
Enable key lock.
Adjustment probe temperature setting ON/OFF delta (see parameter
10-07)
Stove shutdown delay.
Valid only in case of Standby set to ON.
For enabling self-calibration.
For selecting the probe on which stove adjustment is to be set:
- S-AMBI: Ambient probe on stove, connected to the mainboard
- C-I084: Remote graphic display
- T-AMBI: 'Normally open' external ambient thermostat
- T-PUFFER: 'Normally open' external thermostat located on the hot
water storage tank (puffer)
- S-MAND: External probe located on the outlet and connected to the
mainboard
- S-PUFFER: Probe located on the hot water storage tank (puffer) and
connected to the mainboard.
47
-Reinstatement operations must
be carried out by a service
centre.
-The pump starts in order to move
the water inside the heating
circuit.
- Monitor the water temperature
so that it does not fall below 0°C.
- Cleaning - extraordinary
maintenance
maintenance and reinstatement
operations must be carried out by
a service centre.