Herunterladen Inhalt Inhalt Diese Seite drucken

Wiring Diagram; Plumbing Connections - Ferroli TERMO MODENA Installations-, Bedienungs- Und Wartungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 69

2.7 Wiring diagram

2.8 Wiring diagram for zone system
Before installing the heating stove in the house, check the type of heating system;
in case of several zones, a special electronic controller for multi-zone circuits, available as an optional, must be
installed. This is to prevent overheating of the heating chamber due to possible simultaneous closing of the zone
valves and consequent stopping of hot water flow.

2.9 Plumbing connections

The heating capacity of the unit must be previously established by calculating the building's heat requirement
according to current regulations. The system must be provided with all the components for correct and regular
operation; in fact according to the rules of proper workmanship in installation, shutoff valves and non-return valves
allowing the stove to be isolated in case of maintenance and/or checks, must be interposed between the stove and
the heating system. Proceed slowly during heating chamber water filling, to allow correct and complete evacuation
of the air from the vent ( for a closed vessel system from 1.1 to 1.5 bar ).
The pellet stove has an internal heating water circuit complete with circulating pump, safety valve, air vent,
temperature probes and pressure transducer.
To view the value of the device hydraulic system pressure is necessary to access the STOVE STATUS menu M08
and press the P3 button to see the various function.
To connect the heating stove to a DHW system it is advisable to contact a competent technician in order to best
optimise the plumbing connections and the performance of the entire system without compromising stove operation.
For the connection to the DHW circuit it is necessary to install a monostable 3-way valve outside the stove whereas
the circuit is not functional with the DHW pump.
To connect the DHW system 3-way solenoid valve it is necessary to request the optional: supplementary electronic
board model 'O074' for management of commands .
During stove transport the gaskets in the plumbing system may come loose and/or break, causing water leaks during
normal operation; therefore make sure to check the tightness of the circulating pump and heating chamber connection
rings and vent the residual air during water filling and after the first hours of operation.
35
TERMO MODENA

Werbung

Inhaltsverzeichnis

Fehlerbehebung

loading

Inhaltsverzeichnis