4. Once the reservoir is empty, the corresponding warning lamp lights up and the unit shuts down. If your want the unit
EN
to continue to operate, add more water.
VAPO 360° FUNCTIONS
1. Rotary Function of VAPO 360° :
If you want the vapour diffuser tip to rotate, press the rotation control button on the control panel or remote control. The
vapour diffuser tip will begin to turn through 360°. After 10 hours of rotating operation, please stop the appliance for at
least 2 hours to prolong its working life.
2. Timer Function :
Once started, the Vapo 360° humidifier is set in the factory to run until the tank is empty. However, you can set the Vapo
360° operating time. This can vary from 1 to 10 hours. To do this, press the "Timer" control button on the control panel or
the remote control and select your chosen duration by pressing on the
key to increase the duration or
to reduce it.
3. Anion Function :
Press the corresponding key on the control panel or the remote control so that the appliance releases negative ions or not.
4. Vapour emission intensity
It is possible to adjust the intensity of the vapour emitted by the appliance. On the control panel or remote control, select
the level of your choice by pressing the
key to increase the intensity or the
key to reduce it.
Position 1: steam quantity : 80ml/h
Position 2 : steam quantity : 100ml/h
Position 3 : steam quantity : 160 ml/h
Position 4 : steam quantity : 180 ml/h
Position 5 : steam quantity : 260 ml/h
ATTENTION: ALTHOUGH THE UNIT IS FITTED WITH SAFETY MECHANISMS THAT CUT OFF
TRANSDUCER OPERATION, TURN THE UNIT OFF WHENEVER POSSIBLE.

MAINTENANCE AND STORAGE:

If the water is hard, that is to say it contains too much calcium or magnesium, it may deposit a "white powder" inside
the unit and cause a heavy scale on the surface of the reservoir, on the transducer (metallic button producing the
ultrasound) and on the internal walls of the water reservoir. The presence of any scale on the surface of the transducer
will greatly reduce mist production.
We strongly advise you to:
1) Clean the reservoir every 3 days, and to clean the transducer every week;
2) Change the water in the reservoir every two days so that it remains fresh.
3) Clean the unit completely to avoid any risk of bacteria and check that it has completely dried when it is not being
used.
4) Clean regularly the filter.
To clean the transducer:
1) Place 2 to 5 drops of vinegar on the surface and leave for 2 to 5 minutes.
2) Brush away any deposit from the surface using a soft brush. Do not use a hard tool to scrape the surface.
3) Rinse the transducer with clean water.
4) Do not use soap or any other alkaline substances to clean the transducer.