Ensure that the control unit is only used for protection against dangers.
-
Ensure that all safety requirements applying for the machine in question are
observed.
-
Ensure that all European guidelines and national laws/guidelines applying
are observed.
-
Ensure that the switches are always switched over in a deenergized state.
3
Function
The control unit consists of two independent units.
Unit
Components
1
-
-
-
-
2
-
-
-
-
Unit
Can be used as
1
-
-
-
2
-
-
Each unit is equipped with 2 sensor inputs with 2 contact makers each. Each sen-
sor input drives one control output.
NOTE
Each control output allows controlling one SPS.
The safety outputs of this unit switch on when both sensor inputs of a unit are re-
activated.
900565 / 04.04.2016
Sensor inputs S1 and S2
Input external contactor 1 and 2
Safety outputs SA1 and SA2
Control outputs A1 and A2
Sensor inputs S3 and S4
Input external contactor 3 and 4
Safety outputs SA3 and SA4
Control outputs A3 and A4
Control unit
EMERGENCY OFF relay
2-hand control
Control unit
EMERGENCY OFF relay
with cross short detection
with delayed switch-off of control outputs
GB