Max. number of **switching operations
for 3 A switching current
(ohmic load, 250 V AC)
Service in Years
Operating voltage fuse
Fuse safety outputs
Operating temperature
Storage and transportation temperature -25 °C ... +85 °C
Operational standby
Indicators
Connections
Vibration and shock resistance
International protection - housing
International protection - terminals
**The switching cycles apply only to safety outputs.
Cooling-off period
The cooling-off period is the time permitted:
-
between actuation of the first and second contact of a sensor.
-
between actuation of the first and second sensor if the unit is used as a
2-hand control unit.
Actuation
First and second contact of a sensor
First and second sensor (2-hand control unit)

LED displays

LED
1
2
3
900565 / 04.04.2016
Meaning when LED is lit
Operating voltage is applied
Operational standby is on
Sensor 1, both contacts actuated
5
2,5 x 10
20
1 A, fast-action
3 A each
0 °C ... +55 °C
Approx. 2 s
LED
Max. 4 sensors
Vibration: 10 ... 55 Hz, 1 mm
Shock: 30 g / 11 ms
Continuous shock: 10 g / 16 ms
IP 30
IP 20
GB
Period
3 s
0.5 s
21