Herunterladen Diese Seite drucken

Using The Special Features Of The Room Unit; Installer Parameters Table; Category 1 - Room Unit Settings - ACV RC35RF Einbauanleitung

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

EN

3.3 Using the Special Features of the Room Unit

Special Feature:
Description:
Summer/
This feature moves time automatically on the
Winter Auto
last Sunday of March and the last Sunday of
time change
October. The feature is factory enabled.
Temperature
If the Room Unit is located in a particularly hot/
Offset
cold location for reliable signal transmission
reasons then the measured/displayed temperature
can be adjusted by +/- 3°C. This is useful if
the homeowner wants the reading to match
another appliance temperature display.
Upper/Lower
The normal upper temperature limit of 35°C can be
Temperature
reduced to 21°C to save the homeowner energy.
Limit
The normal lower limit of 5°C can be increased
up to 21°C to protect inhabitants from cold.
8
INSTALLATION AND OPERATION MANUAL
Enable/Disable
To enable: Set parameter
3:tC (category 1) to 1.
Set parameter 12:tO
(category 1) to the
required offset value.
Set parameter 6:uL (category
1) to the desired upper limit.
Set parameter 7:LL (category
1) to the desired lower limit.
INSTALLATION AND OPERATION MANUAL

3.4 Installer Parameters Table

3.4.1 Category 1 - Room Unit Settings

Parameter
Parameter
Factory Default Setting
No.
Category 1 Parameters – Room Unit Settings
Display
Description
AM-PM / 24hr
1:CL
24
24 hr clock
Display
display format
Reset Time/
2:rP
1
Time / Temp profile
Temp Program
set to factory default
Changes to 0 when
one of the time/temp
profiles are changed
Auto Summer/
3:tC
1
Auto Summer/Winter
Winter Time
Time Change Enabled
Change
LCD Backlighting
5:bL
1
Backlighting Enable
Upper Temp Limit
6:uL
35
35°C Upper Temp. Limit
Lower Temp Limit
7:LL
5
5°C Lower Temp. Limit
Optimisation
8:OP
0
Optimisation Disabled
Temperature
12:tO
0
No temperature offset
Offset
Proportional
13:Pb
1.5
Proportional band
Band Width
of 1.5 degrees
Reset Parameters
19:FS
1
All settings at
to Factory
factory defaults
Defaults
Changes to 0 when
one of the parameter
is changed
Note
Remember to always press the green
button to confirm that you want to store your
new Installer Set-Up setting. To exit the Installer Mode press the
EN
Optional Setting
Display Description
12
12 hr – AM/PM clock
display format
0
Time / Temperature are as
programmed
To restore the factory
profile set to 1
0
Auto Summer/Winter Time
Change Disabled
0
Backlighting Disabled
21 to
21°C to 34°C adjustment
34
in 1°C steps
5 to 21
6°C to 21°C adjustment
in 1°C steps
1
Optimisation Enabled
-3 to
-3°C to +3°C adjustment
+3
in 0.1°C steps
1.6 to
1.6°C to 3.0°C adjustment
3.0
in 0.1°C steps
0
Settings are as modified above
To restore the factory
profile set to 1
or
button.
9