INSTALLATION GUIDELINES:
 Install the unit in a well-ventilated location where it will not be exposed to high temperatures or humidity.
 Placing and using the unit for long periods near heat-generating sources such as amplifiers, spotlights, etc.
will affect its performance and may even damage the unit.
 The unit can be mounted in 19-inch racks. Attach the unit using the 4 screw holes on the front panel. Be
sure to use screws of the appropriate size. (screws not provided) Take care to minimize shocks and
vibrations during transport.
 When installed in a booth or flight case, please make sure to have good ventilation to improve heat
evacuation of the unit.
 To avoid condensation to be formed inside, allow the unit to adapt to the surrounding temperatures when
bringing it into a warm room after transport. Condense sometimes prevents the unit from working at full
performance.

CLEANING THE APPLIANCE:

Clean by wiping with a polished cloth slightly dipped with water. Avoid getting water inside the unit. Do not
use volatile liquids such as benzene or thinner which will damage the unit.
CONNECTIONS
Connections can be made with balanced/unbalanced XLR-
cables. Please only use good quality balanced cables to
minimize noise and interference. There are many different
possibilities but mainly the unit will be connected between the
output of your mixer and the different amplifiers in your
installation.
IMPORTANT: always test your connections to exclude any wiring errors!
 Make sure all MUTE buttons (8) are on.
 Activate the HF-outputs first: if your cabling is wrong, high frequencies will come out of your
subwoofers (but HF-units are still alive )
FUNCTIONS (FRONT)
1. INPUT SIGNAL METER: Indicates the level of the incoming music signal.
2. OUTPUT SIGNAL METER: Indicates the level of the music signals at the different outputs.
3. MULTIFUNCTIONAL DISPLAY: Indicates the status of the several function settings.
4. PARAMETER ENCODER: endless dial with integrated push button.
Push button: used to browse the different in/outputs
Dial: used to adjust all kinds of parameters, password characters etc. (see further)
5. PREVIOUS BUTTON: used to browse submenu options in backward direction, etc.
6. NEXT BUTTON: used to browse submenu options in forward direction, etc.
7. RECALL BUTTON: used to recall stored programs and quit menus
8. OUTPUT MUTE BUTTONS: used to put the outputs in mute (red LED is lit while in mute mode)
9.  BUTTON: used to select the different parameter values in  direction.
10.  BUTTON: used to select the different parameter values in  direction.
11. SAVE/ENTER BUTTON: used to save programs and confirm options