7 Operation

6.8 Introducing the wire
7 Operation
EN - 16
NOTICE
• Each time the wire is changed, make sure that the beginning of the wire is
free of burrs.
1 Insert the wire in the wire feed unit as specified by the manufacturer.
2 Press the "Current free wire feed" pushbutton at the wire feed unit.
DANGER
Shortness of breath and poisoning caused by inhaling
phosgene gas
During the welding of work-pieces that have been degreased with chlorine-
containing solvents phosgene gas is formed.
• Do not inhale fumes and vapors.
• Ensure sufficient supply of fresh air.
• Rinse work-pieces with clear water prior to welding.
• Do not place degreasing baths containing chlorine in the vicinity of the
welding area.
DANGER
Risk of burns
During welding work spraying sparks, glowing work-pieces or hot slag can
produce flames.
• Check work area for fire.
• Make suitable fire extinguishing materials available at the workplace.
• Allow work-pieces to cool down after welding.
• Prior to performing welding work, fasten the ground clamp properly to
the work-piece or the welding table.
WARNING
Arc burn of the eyes
The arc produced by welding may damage the eyes.
• Wear protective clothing and eye protection.
®