Operating instructions
Anemometer EC-MR330
Item no. 1713920
Intended use
This handy anemometer provides important information about storm force, windchill and
temperature. Power supply is ensured via a 3V/DC battery (type: CR2032).
For safety and approval purposes, you must not rebuild and/or modify this product. If you use
the product for purposes other than those described above, the product may be damaged.
In addition, improper use can cause hazards such as short circuiting, fire etc. Read the
instructions carefully and keep them. Make this product available to third parties only together
with its operating instructions.
This product complies with the statutory national and European requirements. All company
names and product names are trademarks of their respective owners. All rights reserved.
Delivery content
• Anemometer including battery (type CR2032)
• Lanyard
• Operating instructions
Latest operating instructions
Download the latest operating instructions via the link www.conrad.com/downloads or scan the
QR code shown. Follow the instructions on the website.
Explanation of symbols
An exclamation mark in a triangle indicates important instructions in this operating
manual that absolutely have to be observed.
The arrow symbol indicates specific tips and advice on operation.
Safety instructions
Read the operating instructions carefully and especially observe the safety
information. If you do not follow the safety instructions and information
on proper handling in this manual, we assume no liability for any resulting
personal injury or damage to property. Such cases will invalidate the warranty/
guarantee.
a) General
• The device is not a toy. Keep it out of the reach of children and pets.
• Do not leave packaging material lying around carelessly. This may become
dangerous playing material for children.
• Protect the product from extreme temperatures, direct sunlight, strong jolts, high
humidity, moisture, flammable gases, vapours and solvents.
• Do not place the product under any mechanical stress.
• If it is no longer possible to operate the product safely, take it out of operation and
protect it from any accidental use. Safe operation can no longer be guaranteed
if the product:
- is visibly damaged,
- is no longer working properly,
- has been stored for extended periods in poor ambient conditions or
- has been subjected to any serious transport-related stresses.
• Please handle the product carefully. Jolts, impacts or a fall even from a low height
can damage the product.
• After rapid changes in temperature, the product requires approx. 15 minutes to
stabilise, in order to adjust to the surrounding temperature, before it can be used.
For this reason, wait until the product has reached room temperature, before you
use it.
• The product must not get damp or wet.
• In commercial institutions, the accident prevention regulations of the Employer's
Liability Insurance Association for Electrical Systems and Operating Materials are
to be observed.
• Consult an expert when in doubt about operation, safety or connection of the
device.
• Maintenance, modifications and repairs are to be performed exclusively by an
expert or at a qualified shop.
• If you have questions which remain unanswered by these operating instructions,
contact our technical support service or other technical personnel.
b) Battery
• Correct polarity must be observed while inserting the battery.
• The battery should be removed from the device if it is not used for a long period of
time to avoid damage through leaking. Leaking or damaged batteries might cause
acid burns when in contact with skin, therefore use suitable protective gloves to
handle corrupted batteries.
• Batteries must be kept out of reach of children. Do not leave batteries lying
around, as there is risk, that children or pets swallow them.
• Batteries must not be dismantled, short-circuited or thrown into fire. Never
recharge non-rechargeable batteries. There is a risk of explosion!
Features
• Measurement of wind velocity in m/s, ft/min, km/h, ft/min, knots, mph
• Wind speed indication after Beaufort on bar chart wind scale
• Windchill indication
• Background illumination
• Automatic deactivation of the power supply
• Temperature indication in °C (degrees Celsius) or °F (degrees Fahrenheit)
• Lanyard, included in the delivery
Operating controls

Operation

a) Start-up
• If it is the first commissioning remove the battery safety isolation (plastic strap) by pulling it
out of the battery compartment at the backside.
• Press "MODE" (5) and keep it pressed for about 1 second.
• Wind velocity, temperature and the battery state indication icon will be shown on the display.
b) Choosing the unit for wind velocity
To select the unit of the wind velocity, proceed as follows:
• Press "MODE" (5) and keep it pressed for about 3 seconds.
• Now select the desired unit of wind velocity by pressing the key "SET" (11).
The wind velocity can be displayed in
- m/s (= metres per second),
- ft/min (= feet per minute; 1 ft = 30.48 cm),
- km/h (= kilometres per hour), ft/min, knots, mph
- knots (= knots = 1 knot = 1 sea mile/h = 1.852 km/h = 0.51444 m/s)
- mph (= miles per hour; 1 mile = 1.609344 kilometres)
• Press the "MODE" key (5) to save the settings.
c) Selecting the desired wind indication mode
To select the desired wind indication mode, proceed as follows:
• Press "MODE" (5) and keep it pressed for about 3 seconds.
• Now select the desired unit of wind velocity by pressing the key "SET" (11).
The following wind indication modes are available:
- Cu (= Current, indicating the current wind velocity)
- Max. (= Maximum, indicating the maximum wind velocity)
- AVG (= Average, indicating the average wind velocity).
• Press the "MODE" key (5) to save the settings.
1 Temperature sensor
2 Beaufort scale
Wind speed indication after Beaufort on
bar chart wind scale
3 Wind indication mode
You can choose between Cu (=Current,
indicating the current wind speed) Max.
(= Maximum, indicating the maximum
wind speed) or AVG (= Average,
indicating the average wind speed).
4 Battery state indication
5 "MODE" key
6 "°C/°F" key
7 Wind wheel
8 Unit of wind speed
Wind velocity can be displayed in m/s,
ft/min, km/h, ft/min, knots, mph
9 Wind velocity
10 Temperature
The temperature can be displayed in °C
or °F.
11 "SET" key
12 Fastening possibility for a lanyard

Werbung