Service

IMPORTANT! All types of repairs may only be carried out by authorised repairmen. This is so that the operators are not
exposed to great risks.
After 100 hours of operation, the message "Time for servicing" is displayed. The entire equipment shall then be taken to an
authorized Husqvarna dealer for servicing. The message reappears 100 hours after each service.
Error messages
In case of any defects, an error message appears on the display. Follow the directions supplied or contact an authorized dealer.
Fault Code Error message
MOTOR
F01
OVERHEATED
POWER
F02
OVERHEATED
F03
LOW VOLTAGE
F04
HIGH VOLTAGE
F05
OVER CURRENT
NO HALL SENS.
F06
TRAVEL MOTOR
NO HALL SENS.
F07
DEPTH MOTOR
TRAVEL MOTOR
F08
OVERLOADED
DEPTH MOTOR
F09
OVERLOADED
F10
BLADE JAM
GROUND FAULT
F11
OR NO SAW HEAD
NON-COMPATIBLE
F12
SAW UNIT
NO CONTACT
F13
CHECK CAN-
CABLE
NO RADIO
F14
CONTACT

Daily maintenance

Regularly check:
Any abnormal noises.
Make sure to keep the connectors and pins clean. Clean with a rag or brush.
Do not use a high pressure washer to clean the power unit.

MAINTENANCE

Procedure
Water coolant lacking/insufficient
to saw motor.
Water coolant lacking/insufficient
to power unit.
Low voltage supply to the power
unit.
High voltage to the power unit.
Over current to saw motor
Fault on HALL-sensor card for
travel feed
Fault on HALL-sensor card for
depth feeding
Travel motor overloaded.
Depth motor overloaded.
Blade can not rotate.
Incorrect earthing of power pack/
saw or no saw unit connected to
the power pack.
Incorrect saw unit connected to
the power pack.
No contact between power unit
and remote control
No radio contact between remote
control and power unit.
Steps
Check that the water coolant flows to the saw motor and
that it is max. 25ºC and min 3.5 l/min.
Check that the water coolant flows to the power unit and
that it is max 25°C and min 3.5 l/min. If the message pops
up when the blade rotation is started - go to the operations
menu and "Water coolant" and select "ON". Let the water
coolant circulate the power unit for a minute before you turn
the blade rotation on again.
Check the voltage during operation. Check that all three
phases exist. Check that incoming cables have sufficient
cross-sectional area.
Check the voltage during operation. This message is
shown mainly when using a generator as power source.
Check that the power lead is fitted correctly and that it is not
damaged. The message can appear in case of a loose
contact.
Take the equipment to an authorized service shop.
Take the equipment to an authorized service shop.
To reset, reverse the feeding function. If the fault message
returns, grease the feeder gears, clean the rails and adjust
the saw carriage. If this does not help, hand in the
equipment to an authorized Husqvarna service workshop.
To reset, reverse the feeding function. If the fault message
returns, grease the feeder gears. If this does not help, hand
in the equipment to an authorized Husqvarna service
workshop.
Remove the blade from the cut and start the blade rotation.
Check the incoming electrical connection to the power pack
and that the saw unit is connected to the power pack. If this
does not help, hand in the equipment to an authorized
Husqvarna service workshop.
Connect a compatible saw unit to the power pack.
Replace the Canbus-cable.
Check that the power pack is activated and that the green
indicator light is on. If this does not help, hand in the
equipment to a Husqvarna service workshop. The machine
can be used with the Canbus cable between the power
pack and remote control.
– 13