Danger!
!
Do not leave small children unsupervised with the product, packaging
material or small parts. Otherwise there is a risk of fatal injury due to
choking.
!
Perform the connection and installation while the mains power is
disconnected! Otherwise there is a risk of fatal injury due to electric
shock.
!
Do not damage any gas, electricity, water or telecommunication lines
during drilling and fixing work. Otherwise there are dangers of personal
and fatal injury.
!
Treat the supply lines carefully. Lay these so that they cannot be
damaged and do not present any tripping hazard. Fix the cables
sufficiently. Do not pull the cables over sharp edges and do not crush or
crimp them elsewhere. Otherwise there are dangers of personal and
fatal injury.
!
Do not place the equipment near fire, heat or long lasting high
temperature effects of more than +50 °C. Otherwise there is a risk of
fatal injury due to fire.
!
Do not connect any external voltage to the connection terminals.
Otherwise there are dangers of personal and fatal injury and fire.
!
Plug the mains adapter for the mains power connection into the mains
socket completely. Do not touch it with wet hands. Otherwise there is a
risk of fatal injury due to electric shock.
!
Only operate the indoor station and the mains adapter in dry areas. Do
not expose them to dripping or splash water. Only clean the equipment
with a dry and, if necessary slightly moist, cloth. Do not submerge the
equipment in water. Otherwise there is a risk of fatal injury due to
electric shock and fire.
!
Do not connect any damaged device (e.g. transport damage) and
disconnect the power supply immediately in the case of damage.
Unplug the mains adapter from the mains socket. Arrange for the
damage to be repaired immediately by a specialist. Otherwise there is a
risk of fatal injury due to electric shock and fire.
Attention!
!
Only operate the system with 15.0 V
supply. Before connecting the power supply to the mains, ensure that
the mains current complies with 230 V AC, 50 Hz and is fitted with a
fuse according to regulations.
!
Protect the equipment and the cables against strong magnetic or
electrical fields and against strong mechanical loads and vibrations.
!
Only have repairs carried out by authorised and trained qualified
personnel. Otherwise there is a risk of damage due to improper use and
invalidation of the warranty.

Planning the installation

Observe the following points:

Outdoor station

!
!
!
!
!
Indoor station
!
!
!
!
!
DC from the supplied power

Checking the function

!
!
!
!
Protect the outdoor station against direct rainfall.
Mount the outdoor station at such a height that visitors can comfortably
reach the doorbell button and that the face of the person ringing the bell
is in the field of view of the camera.
The outdoor station is usually installed at the side of the entrance door.
Ensure that the face of the visitor standing in front of the door can be
seen on the screen. The horizontal detection angle of the camera is
approx. 45°. If necessary, use the enclosed wedge bracket to align the
outdoor station horizontally.
Arrange the outdoor station so that no direct light falls on the lens
opening. Avoid strong backlighting behind the visitor: in this case, the
person appears darker on the image. Check the camera image before
mounting. Put the unit into operation and hold the outdoor station in the
desired place for this. If necessary, change the position until you have
found the optimum image detail. Remember that the position of the sun
changes.
Suitable, possible cable routing must be available, also for the optional
electric door release.
Mount the indoor station on the wall at a central place inside the
residence, e.g. in the hall. Ensure that the chime can be heard
everywhere inside the residence.
If the chime is not sufficiently audible, an additional indoor station can
be connected.
Arrange the indoor station at face height so that you can observe the
monitor. Take account of the height of everybody living in the residence
including children when determining the mounting height.
Ensure that there is a mains power socket for the mains power supply
within the range of the mains adapter cable.
Pay attention to the length of the necessary connection cable to the
outdoor station. The maximum length is 50 m. A suitable existing cable
can be used if needed (wire cross section min. 0,65 mm², max. length
50 m). One 10 m cable is supplied. Avoid laying the connection cable
directly next to current-carrying lines as this adversely affects the image
and sound quality.
Unpack the equipment and remove all plastic protective packaging.
Provisionally lay the connection cable [20] from the intended
installation location of the outdoor station to the intended installation
location of the indoor station.
Connect the connection cable to the indoor station [6] (see chapter

"Connection").

If applicable, connect an optional door release (not included in the
scope of delivery) with a two-core cable (not included) to the outdoor
station (see chapter "Connection").
GB - 21