Assembly
Important! The fitting must be installed, flushed and
tested after the valid norms.
1. Flush through the supply pipes.
2. Place the mixer including the sealing washer in position
on the sink.
3. Slip the plastic washer, the slide washer, the metall
washer and collar over the hoses and threaded base
and tighten the collar nut by hand. If there is not enough
space, please use only the slide washer and the metal
washer without the plastic washer.
4. Tighten screws.
5. Connect the supply pipes to the isolation valves;
cold right - hot left.
6. Connect the hose with hose nut, taper sleeve, disc and
washer.
7. Mount the hose weight - be careful by the max. drawn
out, otherwise the hose could be crack.
After the assembly!
8. Dismount the handspray and the filter.
9. Flush through the hose.
10. Clean the filter.
11. Mount the filter and the handspray
12. Re-connect down, handscrew (1 Nm).
The hot and cold supplies must be of equal pressures.

Operation

The mixer is activated by lifting the lever handle.
Turning to the left
= warmer water,
turning to the right
= cooler water.
The handspray can be drawn approx. 50 cm out of the
arm lining. The flow is changed from jet to needle spray
by applying slight pressure to the membrane on top of
the handspray. After shutting off the water flow, the mixer
returns automatically to the bath function.
To retract the hose easily it is only possible when the swivel
arm is in the middle position.
If the waterflow drops, clean the filter located between
hose and handspray.
English
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Rate of flow aerator spray
by 0.3 MPa:
Rate of flow shower spray
by 0.3 MPa:
Test certificate:
Hot water limiter: order separatly
Back flow and vacuum breaker
Hansgrohe single lever mixers can be used together with
hydraulically and thermically controlled continuous flow
heaters if the flow pressure is at least 0.15 MPa.
Maintenance non return valve
The non return valves must be checked regularly according
to DIN EN 1717 in accordance with national or regional
regulations (at least once a year).
Spare parts (see page 3)
1
handle
1.1
screw cover
2
flange
3
nut
4
locking screw for handle
cartridge cpl.
5
6
fixing set
7
hose weight
8
hose 1,25 m
9
fixing set for hose connection
handspray assy
10
11
aerator cpl. M24x1 B
12
non return valve
13
non return valve
1
connection hose 900 mm
max. 1 MPa
0.15 - 0.5 MPa
1.6 MPa
max. 80° C
65° C
ca. 11 l/min
ca. 10 l/min
WRAS
35891800
94186000
96014800
94194000
96059000
92730000
95049000
98551000
95048000
96099000
35893803
13914000
95333000
95332000
95313000


Quicklinks ausblenden: