English
Application
Multi telephone, with integrated TFT
colour monitor 8.8 cm, integrated
buttons for light and door release, a
further 6 buttons programmable for
call, remote switching, doormatic,
call disable, single concierge,
emergency call, alarm call etc.
Performance features:
• 8 LED displays, programmable for
call display, reassurance LED in case
of emergency call, call back request,
activated functions such as call
disable, Doormatic, single concierge
etc.
• 3 inputs for connection of storey
and alarm calls, emergency call
buttons, for actuation of remote
switching and signalling functions,
for interfacing the integrated LED
displays
• 2 control outputs as relay contacts
with common reference point,
programmable for the functions
secondary signal, reassurance LED,
potential-free button function and
so on.
• 6 basic configurations can be
selected without other auxiliary
equipment
• Individual configuration with the
aid of system controller SCO 740-...
• Integrated 5-way control button
for operation of the video memory,
zoom, brightness, colour saturation,
date and time setting and control of
the pan/tilt camera
• Integrated video memory for 28
images
• With a suitable SD card, the
memory capacity can be increased to
over 20000 pictures
Electrical voltage
Mounting, installation and servicing
work on electrical devices may only
be performed by a suitably qualified
electrician.
• Observe the DIN EN 60065
standard! When establishing the
electronic connection, observe the
requirements of VDE 0805 or
EN 60950.
• Never lay parallel to high-
frequency conducting or highly
interference-contaminated cables.
• Observe the planning and
installation guidelines for Multi
systems.
Electrostatic charging
As a result of electrostatic charging,
direct contact with the circuit board
can result in destruction of the
device. Direct contact with the circuit
board must therefore be avoided.
Scope of supply
HTV 840-... comprising
• HTV 840-... (base plate and
housing with circuit board), lettering
panel and lettering insert
• Receiver
• Spiral cable
• Dummy card for SD card slot
• Operating instructions for the
end user
• This product information
Installation
Installation can be performed in any
optional form as parallel cabling.
We recommend side circuit or rising
mains systems with storey-by-storey
distribution. The coaxial cables are
installed in star formation from
the storey distribution board. It is
advisable to avoid pure star or
ring-main type systems.
Conductor material
Use twisted-pair, shielded cable
JY(St)Y with 0.8 mm cross-section
as installation material. Cores 1 and
2 must generally be doubled in side
circuits, cores used for video supply
+Vp and 0V must also be doubled.
Range
With 0.8 mm core diameter, the
maximum range is 800 or 1000 m.
Power supply
The system telephones are supplied
with 24 V DC (22-28 V). The supply
voltage must never be permitted to
drop below 22 V under load.
Mounting
The devices are intended as
standard for wall mounting. A
55 mm junction box must always
be provided under the system
telephone cable entry as a terminal
and storage space.
Strip back cable to appr. 80 mm.
1 Recommended mounting height
appr. 1.50 m to centre device.
2 Open the device from the back by
pressing in the locking lever.
3 When mounting directly on the
wall, fasten the base plate using
4 screws, paying attention that
the plate is the right way up (top
marking).
4 When mounting on a switch box,
use the screw openings in the centre
of the device, paying attention that
the plate is the right way up (top
marking).
5 Perform the installation in
accordance with the PS diagram.
Connect the coaxial cable and video
supply on the circuit board.
6 The cores of the installation cable
must be stored inside the free
installation space in the base plate.
7 Insert the coloured plug of the
spiral cable into the socket at the
housing. A distinct click is audible
when the plug is correctly inserted.
8 Insert the other end of the
spiral cable into the receiver until
the plug clicks audibly into place.
This connection can no longer be
detached.
9 Slot the housing into the base
plate and close by applying a light
pressure.
10 Terminal assignment
* Existing storey call button
** Existing alarm button/contact
*** Existing button/contact
11 Connection of inputs and outputs
12 Comparison HT 642-... with
MOM/MOC 611-..., HT 740-... with
MOM/MOC 711-...,
13

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis