Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Data; Declaration Of Conformity; Inserting/Replacing The Battery - Bosch GMS 120 Professional Originalbetriebsanleitung

Vorschau ausblenden Andere Handbücher für GMS 120 Professional:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

OBJ_BUCH-1222-001.book Page 14 Monday, June 28, 2010 9:28 AM
14 | English

Technical Data

Digital Detector
Article number
Maximum scanning depth*
– Ferrous metals
– Non-ferrous metals (copper)
– Live conductors 110 V/230 V (voltage applied)**
– Wood
Automatic switch-off after approx.
Operating temperature
Storage temperature
Battery
Operating life time, approx.
Weight according to EPTA-Procedure 01/2003
*depending on operating mode, material and size of the objects, as well as material and condition of the base
material
**less scanning depth for wires/conductors that are not "live"
Please observe the article number on the type plate of your measuring tool. The trade names of the individual meas-
uring tools may vary.

Declaration of Conformity

We declare under our sole responsibility that
the product described under „Technical Data" is
in conformity with the following standards or
standardization documents:
EN 61010-1:2001-03, EN 61326-1:2006-05,
EN 301489-3:2002-08, EN 301489-1:2008-04,
EN 300330-1:2010-02, EN 300330-2:2010-02
according to the provisions of the directives
2004/108/EC, 1999/5/EC.
Dr. Egbert Schneider
Dr. Eckerhard Strötgen
Senior Vice President
Head of Product
Engineering
Certification
Robert Bosch GmbH, Power Tools Division
D-70745 Leinfelden-Echterdingen
Leinfelden, 29.04.2010
2 609 140 723 | (28.6.10)
Assembly

Inserting/Replacing the Battery

Alkali-manganese batteries are recommended
for the measuring tool.
To open the battery lid 14, press the latch 15 in
the direction of the arrow and fold up the bat-
tery lid. Insert the supplied battery. Pay atten-
tion that the polarity is correct, according to the
representation on the inside of the battery lid.
The battery indicator h always indicates the cur-
rent battery status:
Battery fully charged
Battery has 2/3 of its capacity or less
Battery has 1/3 of its capacity or less
Please change battery
If the measuring tool is not used for a long
period of time, the battery must be re-
moved. The battery can corrode or discharge
itself over long periods.
GMS 120
Professional
3 601 K81 000
120 mm
80 mm
50 mm
38 mm
5 min
–10 °C ... +50 °C
–20 °C ... +70 °C
1 x 9 V 6LR61
5 h
270 g
Bosch Power Tools

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis