Herunterladen Inhalt Inhalt Diese Seite drucken

Conrad Electronic GX106 Bedienungsanleitung Seite 44

Gsm- schaltmodul
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

T1) undercuts the MIN value, the output TMP2 switches. TMP1 and TMP
2 are switched off as soon as the temperature difference is again within
the MIN and MAX range. TMP3 and TMP4 are not switched here.
This temperature control can additionally return a message: When
exceeding the MAX temperature or undercutting the MIN temperature,
the module can return an automatically generated SMS, an e-mail or a
fax with the message text ALARM TEMP.
RESPONSE
The GSM module can send a response SMS stating the statuses of all
inputs and outputs. For this purpose, an SMS or e-mail is sent to the
module with the entered message text, e.g.you send the SMS
RESPONSE.
This text must also always contain 8 characters. If the entered message
text is shorter, you have to enter blanks (marked with stars here:
RESPONSE*).
The response is sent to the number that sent the SMS.
„Always respond with password" means that everyone sending the
password receives a response.
Example:
You send an SMS to the module with the text RESPONSE .
The module responds with:
CONRAD GX106
T1=23C,T2=27C,
TMP1-4=L,L,L,L,
ON:IN1-2=H,L,
SMS1-4=H,L,L,L,
ADC=0mV,PWM=128,
CALL=L,LEVEL=9
-END-
This means that the temperature sensor at connection T1 has mea-
sured 23°Celsius and the sensor at T2 a temperature of 27° Celsius and
that none of the 4 temperature outputs (TMP1-TMP4) has switched on;
both optocouplers IN1 and IN2 are HIGH, the SMS1 output is activated,
the ADC input is 0mV and the PWM output is 0, INCALL was not acti-
44